Replacing Parts (cont'd)
Numbers in parentheses refer to the "Illustration and
Parts List" section of this manual.
Adjusting Knob and Adjusting
Screw Replacement (cont'd)
9. Install the new adjusting screw (7) into the adjusting
knob (5) and install the new retaining ring (8) onto
the adjusting screw.
10. Align the pin (19) in the new blade holder (6) with
the slot in the blade adjusting screw (7). Rotate the
blade holder so the countersink hole is aligned with
the hole in the side of the lever. See figures below.
11. Install the cone point set screw (16) into the lever
(3), and tighten against the countersink hole in the
blade holder (6).
Align countersink with hole in lever.
Greenlee / A Textron Company
Align pin (19) with
slot in adjusting screw.
Align slot with
raised mark.
12. Install new steel ball (13), spring (21), and set screw
(12) into lever (3). (Refer to previous instructions.)
13. Depress the lever (3) to spread open the scoring
tool and reinstall the base (1) and two button head
screws (11).
14. Rotate the adjusting knob (5) clockwise until it
stops. Install the new blade depth scale decal (15)
into the recess on the top of the adjusting knob
with the 0/50 mark aligned with the raised line in the
lever. See figure below.
Apply decal with 0/50
number aligned with
raised mark on lever.
15. Reinstall the blade (18). (Refer to previous
instructions.)
7
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
P2095 • P2096
Turn knob
clockwise
until it stops.