Charging The Integral Battery Pack - Festool SYSLITE KAL II Manual De Instrucciones

Ocultar thumbs Ver también para SYSLITE KAL II:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 24
Compact working light
Charge time of internal battery 90% / 100%
Permitted operating temperature range
Permitted battery temperature for charging
Weight (without external battery pack)
Protection category
Mains power pack
Input voltage
Input alternating current frequency
Output voltage
Output current
Output
Average efficiency in operation
Efficiency at low load (10%)
No-load power consumption
5
Machine features
[1-1] Charging state indicator LED
[1-2] On/off switch with 3 settings
[1-3] Folding attachment handle
[1-4] Connecting socket for charging
adapter
[1-5] Magnetic foot with spherical
head*
[1-6] Adapter plate*
[1-7] Specific charging adapter for
country*
[1-8] Vehicle charging adapter
[1-9] Mains charging adapter*
[2-1] Threaded socket for tripod
UNC 1/4"-20
* not on all versions included in the
scope of delivery
Accessories shown or described are not
always included in the scope of delivery.
The illustrations specified are located at
the beginning and end of the operating
instructions.
6
Operation
Prior to initial operation: charge
battery pack for approx. 4 h!
6.1
Charging the integral battery
pack
► Insert the mains or vehicle charging
adapter into the connecting sock­
et [1-4].
When the light is switched off, the
charging state indicator LED [1-1] dis­
plays the operating state of the internal
English
KAL II
2 h 40 min / 3 h
20 min.
-5 °C to +55 °C
0 °C to +45 °C
0,7 kg
IP 2X
BQ30A-1901200
100–240 V
50–60 Hz
19 V DC
1.2 A
22.8 W
87%
84%
≤ 0.078 W
13