Installation

Installation conditions

Installation location
The pool heat pump must be installed outdoors with a distance greater than 3 m from the Pool
according to laws in force (NF C 15 100).
Install the pool heat pump on a flat, horizontal, and stable surface. (Concrete base would be ideal).
Maintain at least 1 m (40 ") of space on the rear (evaporator air inlet) and 3m (120 ") on the outlet side of
the fan on a completely free space.
Make sure that the discharged air will not be sucked back into the evaporator again.
Provide enough space to allow access to temperature controller.
To improve your installation
Avoid directing the flow of ventilated air towards a noise sensitive area (room window for example), or a space
where people normally gather (the discharged air will be cold)
Avoid positioning the pool heat pump on a surface that can transmit vibrations.
Try to avoid placing the appliance under a tree or exposed to water or mud, which would be likely to complicate
performance and maintenance.

Hydraulic connections

The heat pump should be connected to a filtration circuit trough a by-pass who consists of 3 valves.
It is imperative that the by-pass is placed after the pump and the filter.
These valves allow to regulate the water flow which passes through the heat pump and to isolate the heat pump
completely for any maintenance work, without cutting the filtration flow.
Inlet air flow: 1 m
(40")
Outlet air flow:
3 m (120")