JB Systems Light Plano Spot 7TC Manual De Instrucciones página 7

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

ENGLISH
 Don't forget to set the Blackout mode to 'NO Blackout' or nothing will happen.
Remark: You can connect a CA-8 or LEDCON-02 remote controller to the master unit if you want to
have more control over the master/slave operation.
C. Connect the optional CA-8 controller for more control:
The CA-8 controller can only be used in standalone or master/slave mode. Connect the controller to the
CA-8 input of the first unit (master). Now you can control all the connected units:
BUTTON
STANDBY
1.Synchronous strobe
in white color
Select one of the
2.The same color
different colors.
FUNCTION
chase
3.Different color
strobe
Strobe
Color select
MODE
(LED OFF)
(LED ON)
D. Connect an optional LEDCON-02 controller for more control:
The LEDCON-02 controller can only be used in standalone or master/slave mode. Connect the controller
to the DMX-input of the first unit (master). Make sure that the PLANO SPOT projectors are all set to
channel mode1 (Md 1). Now you can control all the connected units in 4 or 8channel mode. Refer to the
user manual of the LEDCON-02 controller for more information and automatic addressing.
E. Controlled by universal DMX-controller:
 Connect all units together. Refer to the chapter "Electrical installation for two or more units in DMX-
mode" to learn how to do this (don't forget to address all units properly!)
 Connect all units to the mains and turn on the DMX controller.
Since each unit has its own DMX-address, you can control them individually. Remember that each unit
uses 4 DMX-channels as shown in the DMX chart below:
Channel4 can have 4 different behaviors, depending on the channel mode (1,2,3 or 4) you selected.
JB SYSTEMS
®
OPERATION MANUAL
ACTIONS
To blackout all the fixtures
Select one of the 12
Select one of the
different multi-channel
different color fade
shows.
modes.
Show select
Chase select
(LED slow blinking)
(LED fast blinking)
9/54
PLANO SPOT 7TC
ENGLISH
MAINTENANCE
 Make sure the area below the installation place is free from unwanted persons during servicing.
 Switch off the unit, unplug the mains cable and wait until the unit has been cooled down.
During inspection the following points should be checked:
 All screws used for installing the device and any of its parts should be tightly fastened and may not be
corroded.
 Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any
deformation.
 When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced.
 The mains cables must be in impeccable condition and should be replaced immediately when even a
small problem is detected.
 In order to protect the device from overheat the cooling fans (if any) and ventilation openings should be
cleaned monthly.
 The interior of the device should be cleaned annually using a vacuum cleaner or air-jet.
 The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to
optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp,
smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit's optics.
 Clean with a soft cloth using normal glass cleaning products.
 Always dry the parts carefully.
Attention: We strongly recommend internal cleaning to be carried out by qualified personnel!
SPECIFICATIONS
Mains Input:
100-240V, 50/60HZ
Power consumption:
28,5Watt
Fuse:
250V 6,3A slow blow (20mm glass)
IEC input/output daisy chaining:
40pcs
Sound Control:
Internal microphone
DMX connections:
XLR 3pin
LEDs:
7 LEDs 3IN1 3W
Beam angle:
25°
Luminous intensity:
see chart below
Size:
see drawing below
Weight:
2.5 kg
Every information is subject to change without prior notice
You can download the latest version of this user manual on our website: www.beglec.com
JB SYSTEMS
10/54
®
OPERATION MANUAL
PLANO SPOT 7TC

Publicidad

Tabla de contenido
loading

Tabla de contenido