Descargar Imprimir esta página

Technical Data; Eu Declaration Of Conformity - Alto POSEIDON 1200 Instrucciones De Manejo

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 303
9.3

Technical data

Working pressure
Volume flow (max)
Volume flow Q
IEC
Voltage 200 V
/ 3~/ 50Hz
Voltage 200 V
/ 3~/ 60Hz
Voltage 400 V
/ 3~/ 50Hz
Voltage 400-415 V/ 3~/ 50Hz
Voltage 230-400 V/ 3~/ 50Hz
Voltage 220-440 V/ 3~/ 60Hz
Fuse
Power rating
Max. water inlet temperature
Dimensions l x w x h
Weight of cleaner
Weight of spray equipment
Noise level at a distance of
1 m (DIN 45635)
Repulsion power
Suction height
Oil quantity
Oil type
9.4
EU Declaration of
Conformity
42
Poseidon 1280
bar
190
l/h
1280
l/h
1180
JP
JP
DK
EU
N, I, BE, ESP, Unitor
US, EXP, Unitor
A
16
kW
8
°C
85
mm
1020x 480x 940
kg
74
kg
6
dB (A)
75
N
64
m
3
l
0,5
Castrol ALPHASYN - T ISO150
ALTO Deutschland GmbH
Guido-Oberdorfer-Straße 2-8
D-89287 Bellenberg
Product:
Type:
Description:
The design of the unit corresponds
to the following pertinent
regulations:
Applied harmonised standards:
Applied national standards and
technical specifications:
Dipl. Ing. Wolfgang Nieuwkamp
Tests And Approvals
Poseidon 1200
170
1200
1120
DK
EU
N, I, BE, ESP, Unitor
16
7,1
85
1020x 480x 940
71
6
75,4
57
3
0,5

EU Declaration of Conformity

High Pressure Cleaner
Poseidon 1200
Poseidon 1280
400 V 3~, 50 Hz
IP X5
EC Machine Directive
98/37/EG
EC Low-voltage Directive 73/23/EEG
EC EMV Directive
89/336/EEG
EN 292
EN 60335-2-79
EN 55014-1, EN 55014-2, EN 61000-3-2
DIN EN 60335-2-79
Bellenberg, 19.12.2001

Publicidad

loading

Este manual también es adecuado para:

Poseidon 1280