Description Of The Product And Services; Design Of The Monitoring Station (See Figures 1-6); Technical Data - Bosch Deepfield Connect Manual Original

Ocultar thumbs Ver también para Deepfield Connect:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 26
14 | English
Description of the product and
services
Design of the monitoring station
(see figures 1–6)
1 Safety cap
2 Magnet with LED light
3 Transmitter (gateway)
4 Status LED
5 Socket
6 M12 plug connection
7 Transmitter cable
8 Battery
9 Transmitter bracket
10 Cable tie
11 Temperature and air humidity sensor B
12 Superseal plug connection
13 Sensor connecting cable
14 Stake
15 Temperature and air humidity sensor A
16 Soil moisture sensor
17 Screw
18 Battery compartment cover
19 Connector with hook lock
Design of the monitoring system (see figure 7)
20 Sensor system (dependent on product variant)
21 Bosch Cloud (data center)
22 Mobile device, e.g. smartphone or tablet with the app
How it works
You can use the sensors to measure the air temperature and
air humidity. The Soil product variants also include a sensor
with which you can measure the soil moisture.
The sensors are connected to the transmitter. The measure-
ment results are transferred from the transmitter to the Bosch
Cloud via the cellular network. This is where the data is pro-
cessed and saved.
An app installed on your mobile device communicates with
the Bosch Cloud. The app provides a clear display of the mea-
sured values. You can set limit values and configure the app to
warn you if these values are exceeded.
The Bosch Cloud can be simultaneously contacted by multiple
persons in different locations using the app. The app and the
Bosch Cloud communicate over the Internet.

Technical data

Transmitter
Cellular network
Localization
Battery
Battery voltage
Field Monitoring | (10.1.18)
GSM, D2 Vodafone
GPS
– Alkaline manganese
– Not rechargeable
4.5 V
Transmitter
Battery self-discharge
Weight
Storage temperature
Permitted relative air humidity
for storage
Permitted ambient temperature
for operation
Permitted ambient temperature
for operation
Dimensions
Protection category
Temperature and air humidity sensors A and B
Measuring range
– Temperature
– Relative air humidity
Measurement accuracy
– Temperature
– Relative air humidity
Weight
Permitted ambient temperature
for operation and storage
Dimensions
Protection category
Sensor connecting cable
Soil moisture sensor
Measuring range, VWC
Measurement accuracy, VWC
Weight
Permitted ambient temperature
for operation and storage
Dimensions
Protection category
Cable length
App Deepfield Connect – Field Monitoring
Hardware requirements
Operating system
Robert Bosch Start-up GmbH, Deepfield Connect
4 % per year
0,9 kg
+5...+40 °C
30... 70 %
–20...+50 °C
–20...+45 °C
200  112  80 mm
IP 67 (protection against
dust and temporary sub-
mersion)
–20...+80 °C
0...98 % rH
±0.5 °C
±3.5 % (> 25 % rH)
0.34 kg
–20...+45 °C
130  120  105 mm
(without stake)
IP 65 (protection against
dust and water jets)
73 cm
0 ... 57 %
±5.0 %
0.1 kg
–40...+50 °C
51  24  21 mm
IP 67 (protection against
dust and temporary sub-
mersion)
40 cm
Mobile device
(tablet, smartphone)
– Android 5.0
(and later)
– iOS 10.0 (and later)