PROGRAMING
4.3.4 The X Support Program
Operation of special additional systems is made possible through this program such
as: fountains, garden lighting and more.
The X Support Program can be activated only on a weekly mode.
The activation of the additional program is independent. The Master-valve is not
opened. Activation of the sensor, added percentages and Rain Off will not influence
the additional program. Activation of the additional program is suitable only through
the activation of a relay - 24VAC 50mA maximum.
The additional program always operates the last valve on the controller, on controller
AC-8 it is valve number 8, on controller AC-6 it is valve number 6 and so forth.
Programing the X Support Program
Switch the selector to Weekly/cyclic/even-odd mode.
One of the programs will appear on the display : Press the button Pr until the required
X program appears. Continue entering the required data into the X Support Program
in accordance with the instructions for the Weekly activation method - Section 4.2.4
page 13.
PLEASE NOTE
The X additional program can be programed only when the last valve has
not been allocated to any of the irrigation programs.
2
6
EN