3. Operation
■
About the operation method, refer to the operation manual that comes with each remote controller.
3.1. Turning ON/OFF
[ON]
Press the [ON/OFF] button.
The ON/OFF lamp will light up in
green, and the operation will start.
Note:
Even if you press the ON/OFF button immediately after shutting down the operation is progress, the air conditioner will not start for about 3
minutes.
This is to prevent the internal components from being damaged.
■
Operation status memory
Operation mode
Preset temperature
Fan speed
■
Settable preset temperature range
Operation mode
Cool/Dry
Heat
Auto
Fan/Ventilation
3.2. Mode Selection
Press the [F1] button to go through the op-
Fri
eration modes in the order of "Cool", "Dry",
"Fan", "Auto", and "Heat". Select the desired
Room
Cool
Set temp.
Auto
operation mode.
Mode
Temp.
Fan
F1
F2
F3
F4
• Operation modes that are not available to
the connected indoor unit models will not
appear on the display.
What the blinking mode icon means
The mode icon will blink when other indoor units in the same refriger-
ant system (connected to the same outdoor unit) are already operated
in a different mode. In this case, the rest of the unit in the same group
can only be operated in the same mode.
Information for multi system air conditioner (Outdoor
unit: MXZ series)
► Multi system air conditioner (Outdoor unit: MXZ series) can con-
nect two or more indoor units with one outdoor unit. According
to the capacity, 2 or more units can operate simultaneously.
• When you try to operate 2 or more indoor units with 1 outdoor unit si-
multaneously, one for the cooling and the other for heating, the opera-
tion mode of the indoor unit that operates earlier is selected. The other
indoor units that will start the operation later cannot operate, indicating
an operation state in blinking.
In this case, please set all the indoor units to the same operation
mode.
• There might be a case that the indoor unit, which is operating in (AUTO)
mode. Cannot change over to the operating mode (COOL HEAT) and
becomes a state of standby.
• When indoor unit starts the operation while the defrosting of outdoor
unit is being done, it takes a few minutes (max. about 15 minutes) to
blow out the warm air.
6
Remote controller setting
Operation mode before the power was turned off
Preset temperature before the power was turned off
Fan speed before the power was turned off
Preset temperature range
19 – 30 ºC
17 – 28 ºC
19 – 28 ºC
Not settable
Cool
Dry
Auto
Heat
[OFF]
• In the heating operation, though indoor unit that does not operate may
get warm or the sound of refrigerant flowing may be heard, they are
not malfunction. The reason is that the refrigerant continuously flows
into it.
Automatic operation
Fan
■
According to a set temperature, cooling operation starts if the room
temperature is too hot and heating operation starts if the room tem-
perature is too cold.
■
During automatic operation, if the room temperature changes and
remains 2 °C or more above the set temperature for 15 minutes, the
air conditioner switches to cooling mode. In the same way, if the room
temperature remains 2 °C or more below the set temperature for 15
minutes, the air conditioner switches to heating mode.
Cooling mode
15 minutes (switches
from cooling to heating)
Press the [ON/OFF] button again.
The ON/OFF lamp will come off, and
the operation will stop.
15 minutes (switches
from heating to cooling)
Set temperature +2 °C
Set temperature
Set temperature -2 °C