Page 12
ENGLISH
JEP-R Remote Mounting
The variable-speed controller may be remote mounted
onto a vertical surface that is protected from the
elements.
Follow the directions carefully to maintain the ability
to reinstall the variable-speed controller onto the Pump.
Reverse these instructions to complete the reinstallation.
See Figure 8.
ELECTRICAL SHOCK HAZARD
Turn off all switches and the main breaker in the variable-
speed pump electrical circuit, and allow five (5) minutes,
before starting the procedure. Failure to comply may cause
a shock hazard resulting in severe personal injury or death.
Controller Rear
Loosen
to remove
(x4)
Controller
Base
Access Cover
Figure 8.
Disconnect Variable-Speed Controller
from Pump
When determining routing and protection for the
variable-speed controller cabling, ensure that all
National Electrical Code
requirements are met. NEC code requirements
prohibit the routing of signal cables in conduits or
raceways that are used for branch, feeder, or service
conductors. NEC also provides direction for building-
to-building routing of signal cables, with regard to
lightening protection.
Jandy
VS FloPro™ Variable-Speed Pumps
®
WARNING
Pump
Motor
Cover
RS-485 Cable
DO NOT CUT
Power Wiring Port
WARNING
(NEC
) and all local code
®
®
|
Installation & Operation Manual
At the pump:
1.
Remove power from the pump by disconnecting the
high voltage lines or by turning off or deactivating
any breaker to which the pump power is connected.
2.
Lift up the controller cover on its hinges to access
the variable-speed controller.
3.
Remove the six (6) screws to disconnect the
variable-speed controller from the controller base
on the Pump motor.
4.
Detach the RS-485 cable connecting the variable-
speed controller user interface to the controller base
on the motor. Do not over extend the cable when
raising the controller away from the motor.
5.
Unscrew the four (4) connector terminals and
disconnect the wires of the motor cable assembly.
Note: Do not cut the cable, or you will lose the ability to
return to the default factory configuration.
6.
Bundle the loose wire into the pocket of the
controller base. This wire will be used if
reinstalling the variable-speed controller onto the
Pump.
7.
Secure the pocket cover and gasket with six (6)
screws to the variable-speed controller base on the
motor.
8.
Remove the one (1) screw and access cover to
complete electrical connections to the motor.
9.
Insert the free end of the new RS-485 cable through
the available compression fitting and route the
4-conductor cable through the motor drive threaded
port closest to the connector.
10. Prepare the cable and attach another 4-pin
connector, ensuring the wire colors match Figure 7.
11. Insert the RS-485 connector onto the corresponding
RS-485 connector on the motor PCB.
12. Secure the compression fitting nut around the cable
to secure the motor.
13. Verify the DIP switch settings match Figure 7.
14. Reinstall the access cover with the single screw
removed in step 8.
Follow the instructions in the Variable-Speed Controller
User Interface Installation/Owner's manual (H0412200)
to complete the remote mounting of the controller.
To install the JEP-R variable-speed controller:
IMPORTANT
The installer must TURN ON DIP switches 1 and
2 at the pump when connected to the JEP-R or
iQPUMP01 variable-speed controller.
1.
Remove power from the pump by disconnecting
the high voltage lines or by opening any breaker to
which the pump power is connected.