Section 2. General Description; Introduction; Description; Section 3. Installation Information - Jandy VS FloPro VSFHP085AUT Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Page 6
ENGLISH
Listed/certified to the latest
published version of
ANSI
its successor standard,
Cover/Grate or Suction
Fitting, securely fastened to
Figure 1.
Number of Suction Outlets Per Pump

Section 2. General Description

2.1

Introduction

This manual contains information for the proper
installation, operation, and maintenance of Jandy
VSFHP085AUT, VSFHP085JEP, VSFHP165AUT,
and VSFHP165JEP pumps. Procedures in this manual
must be followed exactly. To obtain additional copies
of this manual, contact Zodiac
800.822.7933. For address information, see the back
cover of this manual.
2.2

Description

VS FloPro is a variable-speed pump that can be run
from 600 RPM to 3450 RPM. When connected to the
JEP-R controller, up to eight (8) speed settings may
be programmed and recalled. This allows you to select
the most appropriate speed for your application. Even
more versatile programming is possible when you use
an iQPUMP01, AquaLink
AquaLink Z4™ controller.
The pump is driven by a variable speed ECM
(Electronically Commutated Motor) directly attached to
the pump impeller. The motor spins the impeller which
forces water to flow through the pump. As the speed of
the motor is varied the flow through the pump is also
varied. The adjustable flow rate allows for optimization
of flow during the varying pump cycle requirements. As
a result the energy efficiency of the pump is maximized
resulting in cost savings to the pool owner while also
helping to save the environment.
Jandy
VS FloPro™ Variable-Speed Pumps
®
/ASME
A112.19.8 or
®
®
ANSI/APSP-16.
Anti-entrapment
Main Drain Sump
Suction Outlet
(Main Drain)
Valves permitted only after tee
Customer Service at
®
RS, AquaLink PDA, or
®
At Least
3 Feet
Listed/certified to the latest
ANSI/ASME A112.19.8 or
Fitting, securely-fastened
No valves between
Tee and Main Drains

Section 3. Installation Information

3.1

Plumbing

Preparation Information
1.
Upon receipt of the pump, check the carton for
damage. Open the carton and check the pump for
concealed damage, such as cracks, dents or a bent
base. If damage is found, contact the shipper or
distributor where the pump was purchased.
2.
Inspect the contents of the carton and verify that all
parts are included, see Section 7.1, Replacement
Parts List and Exploded View.

Pump Location

To Reduce the Risk of Fire, install pool equipment in
an area where leaves or other debris will not collect on
or around the equipment. Keep surrounding area clear
of all debris such as paper, leaves, pine-needles and
other combustible materials.
1.
Zodiac Pool Systems LLC recommends installing
the pump within one (1) foot (30 cm) above water
level. The pump should not be elevated more than
five (5) feet above the water level of the pool.
NOTE
The pump is NSF-certified as being able to prime
at heights up to 10 ft above the pool water level, at sea
level. However, to achieve better self-priming, install the
pump as close as possible to the water level of the pool.
2.
If the pump is located below water level, isolation
valves must be installed on both the suction and
return lines to prevent back flow of pool water
during any routine or required servicing.
|
Installation & Operation Manual
published version of
its successor standard,
ANSI/APSP-16.
Anti-entrapment
Cover/Grate or Suction
to Main Drain Sump
Suction Outlet
(Main Drain)
Pump
WARNING

Publicidad

Tabla de contenido
loading

Tabla de contenido