Quick Guide
88
LCP data not compatible
89
Parameter read only
90
Parameter database busy
91
Parameter value is not valid in
this mode
92
Parameter value exceeds the
min/max limits
nw run
Not While Runnin
Err.
A wrong password was
entered
1) These faults are caused by mains distortions. Install a Danfoss line filter to rectify this problem.
Table 1.5 Warnings and Alarms Code List
MG02BB4P
Quick Guide●Kurzanleitung●Guide rapide●Guía rápida●Guia Rápido●Краткое
руководство
X
X
X
X
X
X
X
Danfoss A/S © 05/2016 All rights reserved.
Occurs when copying from LCP if data are moved between
frequency converters with major differences in software
versions.
Occurs when trying to write to a read-only parameter.
LCP and RS485 connection are trying to update parameters
simultaneously.
Occurs when trying to write an illegal value to a parameter.
Occurs when trying to set a value outside the range.
Parameters can only be changed when the motor is stopped.
Occurs when using a wrong password for changing a
password-protected parameter.
1
1
21