Descargar Imprimir esta página

Technical Data - Trotec TDS 20 R Manual Operativo

Ocultar thumbs Ver también para TDS 20 R:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 12
SWITCHING OFF THE HEATER
Let the fan run for 3 minutes before turning the heater
off. Rotate the knob to the "0" position.
REGULATING THE THERMOSTAT
By rotating the knob that controls
the thermostat, you can regulate
the room temperature.
When the desired temperature is
reached the thermostat automatically
switches the resistance off but the fan continues working.
The appliance comes with a built in security device
that goes off automatically if the appliance should
happen to overheat.
If the security device should go off, let the appliance
cool down before looking for the cause of the problem.
Should the problem persist, contact the Service Centre.
SINGLING OUT PROBLEMS
Problem:
The appliance works but does not
heat
The appliance does not switch on
Limited air flow

TECHNICAL DATA

Air displacement
Capacity
Absorbed current
Voltage
Sound level
Size (mm)
Weight
EN
Cause:
Resistance is burnt out
Thermostat control is broken
Faulty motor
Power supply interrupted
Air duct obstructed
Faulty motor
TDS 20 R
305 m³/h
3 kW
13,04 A
230 V / 50Hz
46 dB
250 / 245 / 315
340 / 335 / 410
4,7 kg
Operating Manual – Electric hot air generator
PERIODIC STORAGE AND CONTROL
If the appliance is not used for a long period of time, it
should be cleaned before being put away. Store it in a
dry place and protect it from dust. When the appliance
is used again check to make sure that the electric
cable is not damaged. Should you have any doubts as
to the conditions of the appliance please contact the
Service Centre.
The appliance should be checked at least once a year.
Only qualified personnel authorized by the manufac-
turer must carry out all repairs.
TDS 50 R
980 m³/h
4,5 / 9 kW
5 / 10 / 15 kW
13 A
400 V / 50 Hz
400 V / 50 Hz
55 dB
395 / 380 / 445
10,8 kg
Solution:
Replace
Replace
Replace
Unplug the appliance and check
connection.
Clear the passage
Replace
TDS 75 R
TDS 120 R
1100 m³/h
1900 m³/h
0,15 / 15 / 30 kW
21,7 A
400 V / 50 Hz
57 dB
860 / 565 / 645
19 kg
43,3 A
61 dB
32,5 kg
B - 2

Publicidad

loading

Este manual también es adecuado para:

Tds 50 rTds 75 rTds 120 r