THERMAL CUTOUT PROTECTION
- The water pump and compressor are protected by a
thermal cut-out housed inside the pressure switch
connected to the inverter panel. The mixer motor and the
cell wheel motor are protected at various levels and if
any one of the protection devices trips, this will be
signalled on the display.
ERROR MESSAGES (SHOWN ON PANEL DISPLAY):
- The error messages are shown on the inverter panel
display when specific situations arise:
- ERR 00: Fault module inverter
- ERR 01: Motor overtemperature
- ERR 02: Motor thermal cut-out
- ERR 03: Momentary overload of motor
- ERR 04: Thermal image of motor
- ERR 05: Under-voltage
- ERR 06: Over-voltage
- ERR 07: Water pump protection
- ERR 08: Excessive air loss
- ERR 09: Cell wheel motor blocked
- ""BLOC"": Motor pump blocked
- ""H2O"": Water pressure too low
- ""VOLT""
Note: Refer to the tableTroubleshootingon page 27, for further
information.
12. OPERATION
- The hopper safety grille must be fitted and secured
at all times.
Never place materials other than premixed dry materials
in the hopper.
ON
OFF
FIG.11
IMER INTERNATIONAL S.p.A.
Q6
Q5
Q4
Q1
Q2
1a
Q3
OFF
KOINE 35
1
3
5
10
6
FIG.10
- Opening of the mixing chamber causes shutdown of
the machine moving parts (fig.11). First close the mixing
chamber and press the start pushbutton to start the
machine.
- Wear specified protective devices before working
on the machine
Regulate the water to obtain the required consistency.
Different diameters of deflector are available (10,12,14,16,18
mm):
the smaller deflectors enable improved nebulisation, and the larger
ones are more suited to materials with a larger particle size.
For standard plastering materials the deflector with 14 mm hole
(ref.9b) is used.
However, it is important to measure the distance of the nozzle
(ref.9c) from the outlet so that it is the same as the diameter of
the deflector (fig.12).
If no water is delivered, the machine shuts down.
Before restarting the machine, identify the cause of the problem:
valve closed, delivery hose bent, tank empty, clogged filter (ref.4).