Descargar Imprimir esta página

Temper Koban KT 50HR Manual De Instrucciones página 8

Publicidad

Idiomas disponibles

Idiomas disponibles

KT 50HR
Thermostat for Floor Heating 0769022
[Dimension in mm]
Basic Key and Operation
When the unit is powered on, full screen are on and the unit goes to
Normal Display Mode.
Hold the icon
button (above Figure) for 3 second – to turn on or
off the thermostat.
The following icons meaning:
– floor temperature
– heating ON or OFF status
– setting temperature
P3
– program number (1-6)
Normal Display Mode
Temperature measurement starts. Floor temperature will be
displayed.
˙
Hold the icon
button for 3 second – to turn on or off the
thermostat.
˙
Press the icon Up or Down button – enter to setting temperature
mode
˙
If the floor temperature is lower than the setting temperature,
the heating is turn on and display
˙
If the floor temperature is higher than the setting temperature,
the heating is turn off and
icon disappear.
˙
If the floor temperature is lower than 0°C, the symbol LO is
displayed.
˙
If the floor temperature is higher than 50°C, the symbol HI is
displayed.
˙
If the floor temperature is display "- -", check the sensor cable is
disconnected or damaged.
Time Setting Mode
Setup the weekday and clock.
˙
Press
˙
Press Up or Down button – enter to set the weekday
˙
Press
the Hour
˙
Press
the minute
˙
Press OK button back to Normal mode
Program Setting Mode
Setup the program schedule. 0769022 is a weekly programmable
thermostat with 6 programs for Monday to Friday (1-5) and 2 programs
for Saturday and Sunday (6-7). The start time and the set temperature of
each program are programmable.
1 Press the icon P button to enter to program setting mode
2 The start time is flashing, The programs sequence is Monday~Friday
(12345) -> Saturday~Sunday (67) -> Exit to normal mode
3 Press the icon Up or Down button to adjust the start time of the
program
4 Press the icon P button set program set point
5 Press the icon Up or Down button to adjust the set point of the
program
6 Press the icon P button to set next program start time
7 Repeat the step 3-6 until all program are set, the last program is
Saturday~Sunday (67) P6.
8 The display will return to normal mode.
Default program settings are shown as below:
Program1
(Wake)
Program2
(Out)
Program3
icon.
(Lunch)
Program4
(Out)
Program5
(Back)
Program6
(Night)
button – to enter time setting mode
button show the hour, Press Up or Down button to set
button show the minute, Press Up or Down button to set
Mon – Fri (12345)
Sat – Sun (67)
6:00
6:00
Set point - 25°C
Set point - 25°C
8:00
10:00
Set point - 20°C
Set point - 20°C
12:00
12:00
Set point - 25°C
Set point - 25°C
14:00
14:00
Set point - 20°C
Set point - 20°C
18:00
18:00
Set point - 25°C
Set point - 25°C
22:00
22:00
Set point - 20°C
Set point - 20°C
Manual Override Mode
The Manual Override mode is using to override the program to
temporary or permanent, if temporary override it will be released
until the next program.
˙
Press the icon Up or Down button at normal mode to enter
to Manual override mode
˙
Press the icon P button to select the temporary T or
permanent P
˙
Press Up or Down button to adjust the override
temperature.
˙
Press OK button back to Normal mode
Adjustable Overheat Protection
To adjust maximum setting temperature to prevent the
overheating occur.
˙
Press the icon Up or Down button at normal mode to enter
to manual override mode
˙
Press the Up and Down button both for 3 second, then enter
to adjustable overheat mode, Display "OH" on bottom.
˙
Press the icon Up or Down button – to adjust the maximum
setting temperature (25 - 40C). (default: 40C)
˙
If no pressed any key for 10sec, then auto return to manual
override mode.
Specification
Temperature Measurement:
0 - 50C
Temperature Controllable Range:
5 - 40C
Resolution:
0.5 C
Operation Voltage:
230Vac +/-15%
50/60Hz
Output Rating:
16A max
Sense Type:
NTC 10K
Operating Temperature:
0 - 50°C
Storage Temperature:
-10 - 55°C
Classification of control:
Class II
(Mircro-disconnection on operation)
Electronic control:
Type 2.B
Protection:
IP 21
Sensor cable:
3m
Terminal:
1-4mm
conductor wire
www.grupotemper.com
2
flexible

Publicidad

loading