Example 2 - Service With Start/Pause Button - Favero Electronics CT1X Manual De Uso

Ocultar thumbs Ver también para CT1X:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

To warn the user that the service is about to
terminate, set the time to 1 minute on the start time
of the automatic pause as in ch. 5.5.
In order to set the duration of the interruption, set
the time to 2 seconds as in ch. 5.6.
Repeat these operations for all services present in
the CTx. Once completed, it is possible to exit the
programming as explained in ch. 4.
Fig. 27: Without start/pause button
7.2 Example 2 – Service with start/pause
button
When you wish to provide users with a service (for
example,
a
shower)
characteristics:
Duration of service for 6 minutes.
Give the user 1 minute total of pause time
(for example, for lathering in the shower).
Warn the user that the service is about to be
terminated by interrupting it for 2 seconds at
1 minute before the end of service.
First enter into programming by pressing the
PROG. button (see ch. 4).
Set the service time to 6 minutes by following the
instructions in ch. 5.3.
Set the manual pause to 1 minute as indicated in
ch. 5.4. The service will start in pause mode. Each
time the start/pause button is pressed, the user
activates or interrupts the service.
Once this time has terminated, it will no longer be
possible to interrupt the service.
The service will activate after a manual pause (ch.
5.4) or upon pressing the service start/pause key.
With the start/pause button it is possible to interrupt
the service until the termination of time established
in the manual pause.
Repeat these operations for all services present in
the CTx. Once completed, it is possible to exit the
programming, as explained in ch. 4.
F
E
D
AVERO
LECTRONIC
ESIGN
with
the
following
Pag. 11 / 51
.
Fig. 28: With start/pause button
7.3 Example 3 – Service with output of
additional warning notice without
start/pause button
By activating the warning notice function
the number of available services of the
CTx is reduced by half (except on the
CT1X and CT1Xw).
When you wish to provide users with a service (for
example,
a
shower)
characteristics:
Duration of service for 6 minutes.
Give the user 30 seconds of time for arriving
at the service before activation.
Warn the user with a signal light that the
service is about to be terminated without,
however, interrupting service. The signal
light will illuminate for 30 seconds 1 minute
before the end of service.
First enter into programming by pressing the
PROG. button (see ch. 4).
Set the start of the warning notice to 1 minute as
indicated in ch. 4.8.
Then set the duration of the warning notice to 30
seconds as explained in ch. 4.9.
00182-M01-02-ML - Manuale uso CTx
ENGLISH
with
the
following

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ct2xCt4xCt6xCt8xCt1xwCt2xw ... Mostrar todo

Tabla de contenido