Truma CP W Instrucciones De Uso página 9

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 26
Fresh water tank
The supplied sensor
is designed for tank
heights of 150 mm to 380 mm
external dimensions and for
vertical installation.
Establish the height of the
tank (external dimensions).
Drill the borehole with a
diameter of 38 ± 0.5 mm
at the highest point close
to the middle of the tank
and the cleaning opening.
If necessary, shorten the
measuring rods (see short-
ening table).
Insert the sensor into the
cleaning opening and
screw tight – observe the
correct position of the
sealing ring.
Tighten the nuts by hand.
Shortening table
Tank height
Measuring rod length [mm]
External
dimensions
ws
[mm]
380
370
22
360
22
350
22
340
22
330
22
320
22
310
22
300
22
290
22
280
22
270
22
260
22
250
22
240
22
230
22
220
22
210
22
200
22
190
22
180
22
170
22
160
22
150
22
The table applies for symmetrically shaped tanks.
The volume of non-symmetrical tanks needs to be
determined.
gn
ge
br
gr
ws
ws
br
1/1
gn
ge, gr
3/4
1/2
1/4
br
gn
ge, gr
Original length
81
170
260
78
165
253
76
160
245
73
155
238
71
150
230
68
145
223
66
140
215
63
135
208
61
130
200
58
125
193
56
120
185
53
115
178
51
110
170
48
105
163
46
100
155
45
95
148
44
90
140
43
85
133
41
80
125
39
75
118
38
70
110
36
65
103
35
60
95
Connection
Before connecting or disconnecting the cables, the
supply lines to the battery and mains supply must be
disconnected! Only use the specified cable cross-sections
and fuses of the correct strength!
Install the cables to the tanks and battery II.
Connect the sensors and battery II to the panel. The plug con-
nectors can only be inserted to the correct connection when
they are in the right position.
Ensure that all the catches lock into place.
9

Publicidad

Tabla de contenido
loading

Tabla de contenido