ENGLISH
10
Technical Data
Mixer unit
Art. No
Service connection
Max. Power
Idle speed (1)
Idle speed (2)
Stirrer clamping
Max. stirring extension diameter
Protection class
Degree of protection
Max. stirring volume
Weight
Noise details
Sound power level L
Measured according to EN 60745; Uncertainty K = 3 dB (A)
Wear ear protectors!
Vibration details
Total vibration values (triaxial vector sum) Determined properly EN 60745
Vibration value measured a
Uncertainty K = 1,5 m/s
WARNING: The vibration emission level will vary because of the ways in which a power tool can be used and
may increase above the level given in this information sheet.
The vibration emission level may be used to compare one tool with another.
It may be used for a preliminary assessment of exposure.
An accurate estimate of the vibratory load should also take into account the times when the tool is shut down
or when it is running but not actually in use. This may significantly reduce the vibratory load over the total
working period.
Identify additional safety measures to protect the operator from the effects of vibration such as: maintain the
tool and the accessories, keep the hands warm, organisation of work patterns.
control elements and how to use the appliance
properly. Abide by all the safety measures stated in
the service manual. Act responsibly toward third
parties.
The operator is responsible for accidents or risks to
third parties.
Persons over 16 years of age can only work on the
appliance. An exception includes youngsters trained
in order to reach knowledge under supervision
of the trainer during occupational education.
In case of any doubts about connection and operati-
on refer please to our customer center
WA
h,D
2
Read and understand the operating
instructions before using the
appliance. Familiarise with the
Specified Conditions Of Use
The stirrer may only be used to stir plaster, mortar,
glue or paint.
The device must not be used as a drill or drive
for any other device, e.g. for polishing, grinding,
sharpening, engraving with special adapters.
Do not use this product in any other way as stated
for normal use. Not observing general regulations
in force and instructions from this manual does not
make the manufacturer liable for damages.
GRW 1400
58046
230 V ~ 50 Hz
1400 W
0-700 min
-1
300-650 min
-1
M14
140 mm
II
IP 20
65 l
4,52 kg
100 db (A)
1,695 m/s²