OPEraTiON • Cleaning, care and maintenance
6. Cleaning, care and maintenance
The appliance contains no user serviceable parts.
material losses
- Never spray cleaning spray into the air slot.
- Ensure that no moisture can enter the appliance.
- If a pale brownish discolouration appears on the appliance
casing, wipe it off with a damp cloth.
- Clean the appliance when cold with ordinary cleaning prod-
ucts. Avoid abrasive or corrosive cleaning products.
Note
We recommend having the control components checked
as part of regular maintenance.
f Have a qualified contractor check the safety and
control components no more than 10 years after
commissioning.
© wodtke GmbH - Tübingen.
7.
Troubleshooting
Problem
Room does not
get warm enough.
Appliance does not
get hot.
Room does not
get warm enough
although the appli-
ance is hot.
The room gets too
hot.
Window open de-
tection does not
respond.
"Adaptive start" func-
tion does not work as
required.
"Err" or "E..." is dis-
played.
If you cannot remedy the fault, contact your qualified contractor.
To facilitate and speed up your request, provide the number from
the type plate (000000-000000).
WK01_BA_190718
Cause
remedy
Temperature set too low
Check the selected room
on the appliance.
temperature. Adjust if nec-
essary.
No power supply.
Check position of the ON/
OFF switch, RCD and fuse/
MCB in your fuse box.
Overheating. High limit
Eliminate the cause (dirt or
safety cut-out limits heat-
obstructions at the air intake
ing output.
or discharge). Observe mini-
mum clearances.
Heat demand of the
Remedy heat losses (Close
room is higher than the
windows and doors. Avoid
appliance output.
constant venting.)
Appliance temperature is
Check the selected room
set too high.
temperature. Adjust if nec-
essary.
Detected room temper-
Avoid obstructions to air
ature does not match
changes between appliance
actual room temperature.
and indoor air.
Appliance does not
Wait a while after making
detect a pronounced
settings on the appliance,
temperature drop when
until the room temperature
venting. (Window open
has fully stabilised.
detection requires a
previously stable room
temperature.)
Avoid obstructions to air
changes between appliance
and indoor air.
Manually switch the appli-
ance to standby mode for
the duration of venting.
Window open detection
Switch on window open
is not enabled.
detection in the standard
menu.
This function is only ef-
Use the timer mode for op-
fective in timer mode.
timised heating convenience.
Severely fluctuating
Wait a few days for the be-
room temperature or
haviour to stabilise.
the appliance learning
procedure has not been
completed.
"Adaptive start" function
Switch on the "Adaptive
is not enabled.
start" function in the stand-
ard menu.
Internal fault detected.
Notify the qualified con-
tractor.
Page 20 / 76
|