OPERATING INSTRUCTIONS
5. Vigorously "TapClean"
the HEPA dust cup
Fig. 4
filter on a hard
surface until no more
dust is observed
falling out from
between the pleats of
the filter. (Fig. 4)
6. "TapClean" the debris
screen or rinse under
a faucet until clean.
(Fig. 5) Always air dry
for 24 hours before re-
Fig. 5
installing into the hand
vacuum. Remember
that the debris
Debris
screen must be
Screen
completely dry
before reinstalling in
the vacuum.
7. Replace the debris screen on the
HEPA dust cup filter and reinstall
filter assembly in the vacuum. (not
shown)
TROUBLE SHOOTING GUIDE
PROBLEM
POSSIBLE REASON
1.
Power cord not firmly
HAND VACUUM
plugged into outlet.
WILL NOT
2.
No power in wall outlet.
OPERATE
3.
Needs servicing.
4.
Thermostat has tripped.
1.
Dust cup is full.
HAND VACUUM
2.
Unit clogged.
WILL NOT PICK-UP
3.
HEPA Dust Cup Filter
OR SUCTION
needs cleaning or
POWER IS WEAK
replacing.
1.
Dust cup is full.
DUST ESCAPING
2.
HEPA Dust Cup Filter is
FROM HAND
not installed correctly.
VACUUM
3.
There is a puncture/hole
in HEPA Dust Cup Filter.
HAND VACUUM
HOSE OR
1.
Hose clogged.
BRUSHES WILL
2.
Dust cup is full.
NOT PICK-UP
PLEASE NOTE
: The white pleated
filter material in the HEPA dust cup
filter will discolor over time -This is
NORMAL and will NOT affect the
performance of the filter. If the
HEPA dust cup filter
Is properly
"TapCleaned"
Fig. A
after each use
Wash once a
and suction
month or when
does not return
suction appears
reduced.
to 100%, then
Warning:
Allow 24
we suggest that
hours for drying
the HEPA filter
before replacing in
be "TapCleaned"
unit.
vigorously until no
more dust can be removed, then
rinsed under the faucet and allowed to
air dry for 24 hours before refitting into
the vacuum. (Fig. A) Wash once a
month or when suction appears
reduced.
CAUTION
: The suction hole must be
open, free of any obstructions at all
times. Otherwise, the motor will overheat
and could become damaged.
POSSIBLE SOLUTION
1.
Plug unit in firmly.
2.
Check fuse or breaker. Replace
fuse/reset breaker.
3.
Call 1-800-798-7398 for customer
service.
4.
Turn the unit off and unplug from
outlet. Allow to cool.
1.
Empty dust cup.
2.
Turn unit off and unplug from wall
outlet. Remove HEPA Dust Cup
Filter and check for object(s) in
air duct and remove.
3.
Clean or replace HEPA Dust Cup
Filter.
1.
Empty dust cup.
2.
Review HEPA Dust Cup Filter
instructions.
3.
Replace HEPA dust cup filter.
1.
Remove hose and/or bushes.
Remove obstruction from hose.
2.
Empty and clean dust cup.
6
MESURES DE PRÉCAUTION
Important:
Si la trappe de succion ou le boyau se bloquent, éteignez l'aspirateur et
retirez l'obstacle avant de redémarrer l'appareil.
1.
N'approchez pas l'aspirateur
trop près des éléments
chauffants ou des radiateurs.
2.
Avant d'insérer la fiche d'alimentation
dans la prise murale, assurez-vous
que vos mains sont sèches.
3.
N'aspirez aucun liquide.
4.
Tenez les cheveux, les doigts,
toutes les parties du corps et les
vêtements lâches éloignés des
ouvertures.
5.
Lorsque vous retirez le cordon
d'alimentation de la prise
murale, tirez sur la fiche et non
pas sur le cordon.
6.
Ne ramassez aucun objet
fumant ou brûlant tels que les
cigarettes, allumettes ou cendres
chaudes.
7.
N'utilisez pas l'aspirateur sans son
filtre de coupelle à poussière HEPA.
8.
Avant de commencer à
nettoyer, assurez-vous de
retirer tout gros objet ou tout
objet coupant pouvant
endommager l'aspirateur.
19