Use; Specifications - Weidmuller 1238100000 Transclinic 4i+ Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 1
EN

8. Use

Transclinics are equipment for remotely monitoring voltage and current and
capturing values from photovoltaic field strings.
The values measured are accessible through a "host" via MODBUS.

9. Specifications

Technical specifications according to the table:
Maximum no.
of strings
Maximum current
per string
Measurement
range
Maximum voltage
Supply of modules
Temperature
range
Communication
Analogue input
Number of
analogue inputs
Digital inputs
Number of digital
inputs
Digital output
Number of digital
outputs
Power
consumption
Dimensions
Maximum meas-
urement error
54
Transclinic 4i+
4
30 A DC
3..30 A DC
1000 V DC
19 - 36 V DC
-20 ... +70 °C
MODBUS RS485
RTU
0 ... +10 V or
0 ... 20 mA
2
0 ... 5 V low,
15 ... 24 V high
1
max 30 V DC/AC
50 mA
1
< 1500 mW
225 x 109.5 x 92.2
± 1%
Transclinic 7i+
7
20 A DC
3..20 A DC
1000 V DC
19 - 36 V DC
-20 ... +70 °C
MODBUS RS485
RTU
0 ... +10 V or
0 ... 20 mA
2
0 ... 5 V low,
15 ... 24 V high
1
max 30 V DC/AC
50 mA
1
< 1500 mW
265 x 109.5 x 92.2
± 1%
Transclinic 8i+
8
30 A DC
3..30 A DC
1000 V DC
19 - 36 V DC
-20 ... +70 °C
MODBUS RS485
RTU
0 ... +10 V or
0 ... 20 mA
2
0 ... 5 V low,
15 ... 24 V high
1
max 30 V DC/AC
50 mA
1
< 1500 mW
295 x 109.5 x 92.2
± 1%
Transclinic 14i+
14
20 A DC
3..20 A DC
1000 V DC
19 - 36 V DC
-20 ... +70 °C
MODBUS RS485
RTU
0 ... +10 V or
0 ... 20 mA
2
0 ... 5 V low,
15 ... 24 V high
1
max 30 V DC/AC
50 mA
1
< 1500 mW
370 x 109.5 x 92.2
± 1%

Publicidad

Tabla de contenido
loading

Tabla de contenido