Comunello CU 24V 1M ONE Instrucciones De Uso página 23

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

O
1
2
3
4
5
6
7
8
9
N
DIP 1 ON = Step-by-Step Operation
NOTE: A variation of the dip-switches requires pressing the RESET
button on the control unit to activate the new setting.
AUTOMATIC CLOSING:
The control unit can be set up to close the gate automatically without
sending any additional commands.
O
1
2
3
4
5
6
7
8
9
N
DIP 4 ON = Automatic Closing activated (pause time 30 secs)
NOTE: A variation of the dip-switches requires pressing the RESET
button on the control unit to activate the new setting.
IMPORTANT: In STOP status (e.g.: step-by-step command, photocell in
STOP, stop due to obstacle detection, key switch in STOP, I/O board
with STOP input) automatic closing is not allowed. In this case, a further
opening or closing command is always required.
PEDESTRIAN OPENING:
Using both the remote control (encoded as PED) and the accessory control
devices connected to the BUS with PED function activates the pedestrian
opening on the first operator: in the case of a dual swing gate installation,
it opens completely the primary leaf (operator 1), while the second remains
closed. In the case of a sliding gate installation, the command opens the
gate by 30% of its maximum stroke.
STOP
The control unit allows the connection of accessory control devices to
the BUS with STOP function (e.g.: step-by-step command, photocell
in STOP, stop due to obstacle detection, key switch in STOP, I/O board
with STOP input, input 8K2). Pressing this pushbutton irrespective of the
current operating phase of the control unit will immediately stop movement.
A further motion command will be valid provided the stop command has
been disabled.
If an AUTO-PP command is sent (while in the automatic operation mode), a
reverse gate stroke will be activated.
PHOTOCELLS:
Digital ONE photocells can be powered by and connected to the control
unit in accordance with directive EN 12453. By setting the single photocell
RX (receiver) operation via the corresponding dip-switches on the board
(par. SETTING THE ACCESSORY OPERATION (MODE) ) the following
operating modes will be available:
RX PHOTOCELL TYPE 1 "ON CLOSE":
If the photocell is engaged during closing, it runs a full inversion (opening)
of the gate.
The photocell is not active during opening.
RX PHOTOCELL TYPE 2 "ON OPEN":
If the photocell is engaged during opening, it stops the gate until
disengagement (re-starts opening).
The photocell is not active during closing.
RX PHOTOCELL TYPE 3 "ON OPEN+CLOSE":
If the photocell is engaged during opening, it stops the gate until
disengagement (re-starts opening).
If the photocell is engaged during closing, it runs a full inversion (opening)
of the gate.
RX PHOTOCELL TYPE 4 "ON STOP":
If the photocell is engaged during opening or closing, it permanently stops
the gate (also with automatic closing enabled). A new command is needed
to restore operation of the automation.
OPENING AND CLOSING LIMIT SWITCHES:
The control unit allows the connection of an opening limit switch (FCA) and
a closing limit switch (FCC) of NC type. Tripping of the limit switches in
the associated operating phases causes immediate stopping of operator
movement.
NOTE: The FCA and FCC limit switches act only on Operator 1 (installation
10
10
of automation with single operator).
Input terminal to connect the opening limit switch (FCA) and closing limit
switch (FCC) - NC.
NOTE: Do not jumper these inputs if they are not used.
OPERATOR SPEED ADJUSTMENT (SPEED):
The electronic control unit is equipped with a "SPEED" trimmer for operator
speed adjustment, completely managed by the microprocessor. Adjustment
can be performed in a range between 10% and 100% of maximum speed
(clockwise).
NOTE: A variation of the "SPEED" trimmer requires pressing the
RESET button on the control unit to activate the new setting.
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
OBSTACLE DETECTION (SENS):
The electronic control unit is equipped with a "SENS" trimmer for adjustment
of the opposing force required to detect the presence of an obstacle,
completely managed by the microprocessor. Trimmer adjustment basically
determines the obstacle sensitivity (clockwise), i.e. with minimum sensitivity,
1
2
3
4
5
6
7
8
9
10
you will have maximum force and vice-versa.
NOTE: Obstacle detection causes a brief reversal of the gate closing
manoeuvre and commands a STOP on opening.
DECELERATION (SLOWING):
The operator deceleration function is used on gates to prevent the moving
leaves from slamming at speed into the limit stops at the end of the opening
and closing phases.
Using the "SLOWING" trimmer, you can adjust the speed during the
deceleration phase. By turning the trimmer clockwise, you will increase the
speed during deceleration and vice-versa. The deceleration phases are
settable as follows:
O
1
2
3
4
5
6
7
8
9
N
DIP 3 ON = Deceleration after 60% of the maximum stroke
DIP 3 OFF = Deceleration after 80% of the maximum stroke
NOTE: A variation of the dip-switches requires pressing the RESET
button on the control unit to activate the new setting.
OPERATOR ENCODER:
The control unit requires connection of an Encoder for the operator. The
Encoder allows the control unit to detect obstacles and ensures enhanced
precision during gate manoeuvres.
NOTE: The control unit allows the exclusive use of an Encoder with two
non-polarised wires fitted on the ONE line gear motors.
COMUNELLO ®Copyright 2017 - All rights reserved
10
23

Publicidad

Tabla de contenido
loading

Tabla de contenido