3. Operation
<Saving the settings>
OU silent mode
Mon
Tue Wed Thu Fri Sat Sun
Start
Stop
Silent
-
Setting display:
day
F1
F2
F3
F4
<Exiting the Main menu screen>
Fri
Room
83ºF
Cool
Set temp.
Auto
83
ºF
Mode
Temp.
Fan
F1
F2
F3
F4
<Display of unsupported functions>
Title
Not available
Unsupported function
Return:
F1
F2
F3
F4
3.5.2 Vane·Vent. (Lossnay)
<Accessing the menu>
Main
Main menu
Vane·Louver·Vent. (Lossnay)
High power
Timer
Weekly timer
OU silent mode
Main display:
Cursor
Page
F1
F2
F3
F4
<Vane setting>
Fri
Swing
Off
Off
Vane
Vent.
Louver
F1
F2
F3
F4
8
Select the desired item, and press
the [SELECT] button.
The screen to set the selected item
will appear.
Press the [RETURN] button to exit
the Main menu and return to the
Main display.
If no buttons are touched for 10
minutes, the screen will automati-
cally return to the Main display.
Any settings that have not been
saved will be lost.
The message at left will appear if
the user selects a function not sup-
ported by the corresponding indoor
unit model.
Select "Vane·Louver·Vent. (Loss-
nay)" from the Main menu (refer to
page 7), and press the [SELECT]
button.
Press the [F1] or [F2] button to go
through the vane setting options:
"Auto", "Step 1", "Step 2", "Step 3",
"Step 4", "Step 5" and "Swing".
Select the desired setting.
Auto
Auto
Step 1
Step 2
Step 3
Step 4
Step 5
Swing
Swing
Select "Swing" to move the vanes
up and down automatically.
When set to "Step 1" through "Step
5", the vane will be fixed at the se-
lected angle.
Fri
83ºF
Room
Cool
Set temp.
Auto
83
ºF
Mode
Temp.
Fan
<Vent. setting>
Fri
Low
Vent.
F1
F2
F3
F4
<Returning to the Main menu>
Main
Main menu
Vane·Louver·Vent. (Lossnay)
High power
Timer
Weekly timer
OU silent mode
Main display:
Cursor
Page
F1
F2
F3
F4
Note:
During swing operation, the directional indication on the screen
does not change in sync with the directional vanes on the unit.
Available directions depend on the type of unit connected.
In the following cases, the actual air direction will differ from the
direction indicated on the remote controller display.
1. While the display is in "STAND BY" or "DEFROST" states.
2. Immediately after starting heat mode (while the system is wait-
ing for the mode change to take effect).
3. In heat mode, when room temperature is higher than the tem-
perature setting.
<[Manual] To Change the Airfl ow's Left/Right Direction>
* The louver button cannot be used.
• Stop the unit operation, hold the lever of the louver,
and adjust to the desired direction.
* Do not set to the inside direction when the unit is in
the cooling or drying mode because there is a risk
of condensation and water dripping.
Caution:
To prevent falls, maintain a stable footing when operating the unit.
under the vane setting icon
This icon will appear when the
vane is set to "Step 2" to "Step 5"
and the fan operates at "Mid 1"
to "Low" speed during cooling or
dry operation (depends on the
model).
The icon will go off in an hour, and
the vane setting will automatically
change.
Press the [F3] button to go through
the ventilation setting options in the
order of "Off", "Low", and "High".
* Settable only when LOSSNAY
unit is connected.
Off
Low
High
Off
Low
• The fan on some models of in-
door units may be interlocked
with certain models of ventilation
units.
Press the [RETURN] button to go