Economy Operation - Fujitsu AIRSTAGE UTY-RNK Serie Manual De Funcionamiento

Ocultar thumbs Ver también para AIRSTAGE UTY-RNK Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 32
Room temperature sensor selection
Press the ECONOMY button for more than 2 seconds to
select whether the room temperature is detected at the in-
door unit (remote sensor) or the remote controller.
When the
thermo sensor display appears, the room
temperature is detected at the remote controller.
NOTES
This function is locked at the factory. In order to detect the room temperature correctly, consult authorized service
personnel when using this function.
If this function is locked, the location where the room temperature is detected cannot be changed and the
flashes when the ECONOMY button is pushed for 2 seconds or more.

ECONOMY OPERATION

Begin Air Conditioner operation before performing this procedure.
To Use the ECONOMY Operation
Press the ECONOMY button.
"ECO" appears on the Remote Control Unit display.
Economy operation begins.
To Stop the ECONOMY Operation
Press the ECONOMY button again.
"ECO" disappears from the Remote Control Unit display.
Normal operation begins.
About ECONOMY Operation
Economy operation can be set by remote controller.
The temperature setting is offset automatically over a certain period of time.
Based on temperature set in remote control unit, temperature of indoor unit varies little by little. However in this case, tem-
perature indication of remote control unit does not vary as it continues to indicate the temperature when ECONOMY Opera-
tion was set.
Save temperature
Cooling set temperature
Heating set temperature
Save temperature
°C
Cooling
2
Operation
1
0
0
1
Heating
2
Operation
3
4
Start
0
30
60
90
ECONOMY operation
Indoor unit
Min.
mark
En-4

Publicidad

Tabla de contenido
loading

Tabla de contenido