7.3
Connecting pneumatic tools
WARNING
Risk of injury
X
Make sure that the pneumatic tool is
switched off before connecting or discon-
necting.
If
the
compressed
(496141) is installed, the automatic switch-
on function of the mobile dust extractor also
works in combination with pneumatic tools.
We also recommend installing the VE service
unit (495886). The service unit filters and lu-
bricates the compressed air and enables an
adjustment of the air pressure. An IAS
adapter (454757) is available to connect Fes-
tool pneumatic tools to the IAS system.
The operating pressure of the tool must be
6 bar for the automatic switch-on unit to
function correctly.
7.4
Adjusting the suction power
You can use the suction power adjuster [1-
9] to adapt the machine suction power to
different applications.
7.5
Applying the brake
Folding out the black brake lever [1-15] pre-
vents the mobile dust extractor from rolling.
To achieve this, lift the front end of the mo-
bile dust extractor slightly and push the
black brake lever downwards until it latches
into place. Push the green lever [1-14]
again to release.
7.6
Temperature cut-out
To prevent overheating, a temperature cut-
out switches the mobile dust extractor off
when it reaches a critical temperature.
X
Switch off the mobile dust extractor and
allow to cool for about 5 minutes.
L If the mobile dust extractor will not switch
on again, please contact a Festool service
workshop.
7.7
Changing the filter bag (SC-FIS-
CT26/48)
Removing the filter bag [4]
X
Open the locking clips [2-2] and remove
the top section of the machine[2-1].
air
module
[1-3]
X
Remove the filter bag.
X
Dispose of the used filter bag in accor-
dance with statutory regulations.
X
Clean the dust container [2-3].
Inserting the filter bag [5]
X
Insert a new filter bag(SC-FIS-CT26/48)
in the inlet port of the dust container and
interlock it. Important: be aware that
the locking engages.
L Make sure that the filter bag is not
pinched between the top and bottom sec-
tions.
X
Replace the top section [2-1] and close
the locking clips [2-2].
7.8
Changing the safety filter bag
(FIS-CTH 26/48)
Always use the safety filter bag for ab-
sorbing Class H dust.
Removing the safety filter bag [6]
X
Close off the extractor opening [1-2] us-
ing the sealing plug [1-1].
X
Open the locking clips [2-2] and remove
the top section of the machine[2-1].
X
Knock the material of the plastic bag up-
wards and close the lateral openings with
the adhesive tabs.
X
Close the plastic bag around the filter bag
using the cable ties supplied.
X
Remove the safety filter bag
X
Dispose of the used safety filter bag in ac-
cordance with statutory regulations.
X
Clean the dust container [2-3].
Inserting the safety filter bag [7]
X
Insert a new safety filter bag (FIS-CTH
26/48) on the inlet nozzle of the container
and lock in position. Important: Ensure
the lock is snapped in.
X
Place the plastic bag over the edge of the
container. The lateral openings on the
safety filter bag must be positioned inside
the dirt trap.
Ensure the contacts are [10-2]free.
LMake sure that the filter bag is not
pinched between the top and bottom
sections.
X
Replace the top section [2-1] and close
the locking clips [2-2].
CTH