Technical Description
The battery tester provides a complete set of test functions for testing 12 Volt lead-acid and AGM batteries.
The diagnostic results are shown on the LCD display and by coloured LEDs.
• Use at an ambient temperature of -18°C to 50°C (0°F to 122°F).
• "State of Health" display – maximum possible capacity of the battery in comparison with the
original battery capacity.
• "State of Charge" display – current charge level of the battery.
• Battery standards: 200-900 A EN/SAE, 120-550 A DIN/IEC, 200-850 CCA
• Conversion table for JIS standard on the back of the unit
• Integrated voltmeter for 5.5 – 19.99 VDC
• Power supply of the system via the battery to be tested
8
Safety Advice
Before connecting the system, all electrical consumers of the vehicle must be switched off , particularly
the ignition.
See the type label of the battery to be tested or the specifi cations provided by the battery manufacturer
for the information required for testing the battery. Check the battery for damages and the battery acid
level.
If the battery acid level is low, replenish and fully charge the battery.
Observe the necessary cautions when working near batteries to avoid injury.
In this context, please always observe the safety advice and regulations of the battery and vehicle
manufacturers.