Disposal; Technical Data; Data - ProMinent DULCOTEST ICT 1 Instrucciones De Servicio

Sensor de conductividad inductivo
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Disposal / Technical data
Measured variable
Applications
Dimensions (L x W)
Cable feed
Sensor housing
Sensor shaft
Union nut
Conductivity measurement
Measurement accuracy
Reproducibility
Cell constant
Temperature gauge
Temperature compensation
38
13

Disposal

IMPORTANT
Please observe the applicable national regulations.
You may return the decontaminated used equipment to ProMinent
Dosiertechnik GmbH, Heidelberg, against prepaid postage.
14

Technical data

14.1

Data

General information
Electrolytic conductivity
Contaminated wastewater of any type, desalination in cooling towers,
control of electroplating baths, Cleaning in Place (CIP), product
monitoring
Technical design
208 x 80 mm
M 20
Weight
approx. 1 kg
Materials
PP
PP
PVC
Sensor characteristic values
range
0.2 ... 1000 mS/cm (compensated)
< 1 % related to the measured variable limit value
≤ 0.5 % of the measured value
-1
8.5 cm
± 5 %
Pt 100
0...70 °C
ProMinent
®

Publicidad

Tabla de contenido
loading