FX
Surface Cleaning Discs
-Clean without gouging
-Strip paint and coatings
-Remove rust and scale
-Remove adhesive labels
4 ½" 07-X 845 Use only with 4" diameter backing pads
6"
07-X 860 Use only with 4 ½ diameter backing pads
* Can replace wire brushes
* Open web structure which resists loading
QUICK-STEP
Trial Pack
The answer to all your finishing needs, from weld blending to a mirror #8
finish.
Includes: 1 backing pad, 1 flap disc ( grit 10),9 Blendex discs (1 extra
coarse, 2 coarse),3 medium (2 fine and 1 super fine), 1 felt disc, 1 high
polish disc, 1 mini white paste and 1 mini blue paste.
4 ½" M14x 2.0
07-Q952
4 ½" 5/8" – 11
07-Q 953
MOUNTING INSTRUCTION
The WALTER QUICK-STEP is a patented, fully integrated surface
finishing system for use on portable angle grinders/sanders.
-Use only specially designed WALTER QUICK STEP discs on QUICK-
STEP backing pads for safety performance.
-To mount disc on pad, center disc over pin and press firmly onto pad.
-Make sure that you apply pressure around the center of the disc so that the
center hole is firmly pushed over the centering pin of the pad.
-Slight torquing of disc against pad before starting will increase initial
adherence.
Max RPM ; 4,500
Optimal RPM ; 2, 000 to 3, 000
14
SAFETY INSTRUCTIONS
-Do not exceed rated maximum RPM.
-Wear eye, face and body protection.
-Use in properly ventilated areas.
-Keep contact surface of backing pad clean.
-Maintain working and of 2 to 5 with the work piece for best results.
-Store the QUICK-STEP flap discs in an area with 50% humidity at 21° C
( 70° F).
CARBON BRUSHES
When the carbon brushes are worn down, the Auto-Stop feature will
automatically turn the machine off in order not to damage the motor.
The brushes must then be replaced. Use only genuine WALTER carbon
brushes. These brushes are specially made for this tool; they will maintain
its high performance standard and ensure maximum life of the motor.
To check or replace carbon brushes:
1. Disconnect the tool from power supply.
2. Remove motor housing cover.
3. Carbon brushes may be pulled from their holders after lifting spring and
detaching the connector.
4. Replace brushes if necessary. Always replace them in pairs.
5. Check that the new brushes move freely in their holders. To help seat the
carbon brushes properly after they have been installed, use the power
tool without applying a heavy load for at least 30 minutes.
However, when the carbon brushes require replacement, it is recommended
that the tool be sent to a WALTER Factory Service Center or a WALTER
Authorized Service Center. Apart from changing the brushes, your power
tool will be cleaned, inspected and lubricated as required. If new parts are
necessary, only genuine WALTER replacement parts will be used.
PREVENTIVE MAINTENANCE
Your WALTER power tool should be properly maintained to insure
continued high performance. Use low pressure compressed air to blow
out dust from the motor through the vent openings. Clean dust and dirt
deposits from the exterior of the tool. Clean the power cord to prevent
deterioration from oil and grease and check for possible damage.
Note: Damaged cord sets must be replaced. Refer
to Spare Parts List for the ordering number.
15