Planning
Installation examples:
Example 1:
-
The base fan lies in the base area of the kitchen.
-
The air recirculation unit is located between the
kitchen cabinets.
-
The depth of the cabinets has been shortened
for this purpose.
-
The air recirculation unit is located centered behind
a cabinet to guarantee access through the back
wall of the cabinet for maintenance work.
Example 2:
-
The base filter lies in the base area.
-
The air recirculation unit lies in a so-called
-
"dead corner" of the kitchen.
-
For maintenance work, the unit is accessible
through the back wall of the cabinet.
Example 3
-
If the air recirculation unit is placed in an adja-
cent room or in the cellar, the cleaned air must
be returned to the kitchen using the air return
hood (can be ordered separately).
-
If the air return fails, please observe the infor-
mation regarding exhaust air operation in the
operating instructions of the cooktop extraction
fan.
-
The air recirculation unit with the air return
hood and the fans are attached to the ceiling of
the cellar/installation room located below.
-
The cleaned air is returned to the room through
the base area.
Note:
Please note that two fans are required for this installation option.
This installation option is only possible with components from the BORA Professional range.