CHAPTER 4

ELECTRICAL CONNECTION

DANGER - ELECTRIC SHOCK RISK
The electrical connection must be performed by qualified personnel in accordance with the regulations of
each country.
Before carrying out any manipulation inside the appliance, it must be disconnected from the electrical mains.
Incorrect connections can damage the electronic board. The manufacturer is not deemed to be responsible for
damage caused by incorrect connections.
Verify that the power supply is between 110-230V. If the version without cables has been purchased, follow the
indications of diagram B:
• Use H07RN-F 3G1 or 3G1.5 cables
according to the established
power.
• Connect U, V y to the motor.
USER INTERFACE
The following table summarises the meaning of the different elements of the interface where:
• O means led on.
DISPLAY
OPERATION MODE
SET-UP MODE
ALARM MODE
LOW CONSUMPTION MODE
BASIC CONFIGURATION
ADVANCED CONFIGURATION
LED
STATUS
0
bar
( ( O ) )
0
psi
( ( O ) )
0
A
( ( O ) )
0
start
( ( O ) )
0
stop
( ( O ) )
0
( ( O ) )
(((O)))
• Connect L1, N y to the mains.
• The earthing conductor must
be longer than the others. It
will be the first to be connected
• ( ( O ) ) means slow intermittence.
ACTION
It shows instantaneous pressure or instantaneous current consumed
It shows intermittent starting pressure.
It shows intermittent stopping pressure.
It shows intermittent nominal intensity
It shows the alarm code
It shows 3 flashing points
It shows the basic parameters of the configuration
It shows the advanced configuration window
ACTION
It indicates instantaneous pressure in bar
It indicates instantaneous pressure in bar + pump started
It indicates instantaneous pressure in psi
It indicates instantaneous pressure in psi + pump in operation
Indicates the instantaneous current consumed in Ampere
Pump ON
It displays the operating pressure
Operating pressure setting
Stop pressure display
Stop pressure setting
Alarm insufficient water or definitive overcurrent.
Alarm insufficient water with ART activated or overcurrent making attempts at restoration
Rapid cycle alarms
USE AND MAINTENANCE MANUAL
during the connection process
and the last to be detached
during disconnection. Earthing
conductor connections are
mandatory.
• (((O))) means fast intermittence.