Instructions for drive unit
12
Instructions for drive unit
A
CAUTION!
z The parking compressor is only suitable for use with chilled goods. Use for
freezing is not possible!
z Carefully remove the compressor safety cap, as this is filled with inert gas!
z The first time the parking cooling is used, the parking compressor must be
briefly switched on and off at least 5 times otherwise there is a the risk that
the compressor may be damaged!
z When operating the parking cooling, a condenser fan must also be in op-
eration while the compressor is running!
z Ensure that the electronic motor is always well ventilated!
z When installing in an enclosed seat console, an additional opening may
have to be created!
I
NOTE
z The compressor already has the relevant quantity of oil.
z The compressor already has the correct O-rings for the connection adapt-
er.
z When using the rubber dampers to install the drive unit, an additional earth
cable must be laid for the parking compressor.
z After the first test-run of the parking cooling, the V belt should be checked
for the correct voltage.
z When laying the suction line in the interior, it must be insulated against pos-
sible condensation. This also applies to the connection fitting directly on
to the parking compressor.