Troubleshooting

12
Troubleshooting
Problem
Cause
Roof air condi-
Icing sensor has tripped.
tioner constantly
switches itself off.
No cooling
The roof air conditioner is not set to
capacity
cooling.
The ambient temperature is above 52 °C. The roof air conditioner is only
The temperature set is higher than the
room temperature.
The ambient temperature is below 16 °C. The roof air conditioner is only
One of the temperature sensors is
defective.
The vaporiser fan is damaged.
The condenser fan is damaged.
The ambient temperature is above 30 °C. ➤ Only use the heating function of
No heating
capacity
The ambient temperature is below 2 °C.
The temperature set is above 30 °C.
The roof air conditioner is not set to
heating.
One of the temperature sensors is
defective.
Low air output
The air intake section is clogged up.
The blower is defective.
Water enters the
The condensation water drainage open-
vehicle
ings are clogged up.
The seals are damaged.
34
Dometic FreshLight
Remedy
Outer temperature is too low or all air
nozzles are closed.
➤ Set the roof air conditioner to
cooling.
designed for ambient temperatures of
up to 52 °C.
➤ Select a lower temperature.
designed for ambient temperatures
above 16 °C.
➤ Contact an authorised workshop.
the roof air conditioner at
temperatures below 30 °C.
The heating function of the roof air
conditioner is only designed for
ambient temperatures of up to 2 °C.
➤ Select a lower temperature.
➤ Set the roof air conditioning to
heating.
➤ Contact an authorised workshop.
➤ Remove any leaves and other dirt
from the ventilation grilles of the
roof air conditioner.
➤ Contact an authorised workshop.
➤ Clean the drainage openings for
condensation water.
➤ Contact an authorised workshop.