Controller; Chlorination Cell; Accessory Holder; Salt/Temperature Sensor - cec C’El X Manual De Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

1
CONTROLLER (distance from the cell = 2m maximum)
Choose a location that is easily accessible, close to the pump timer. Install the controller vertically,
far enough away from the pool to comply with the regulatory distance in force in your country.
Install the mounting kit on a wall, then encase the controller on the latter
The controller must be permanently connected to the pump timer and servo controlled by the pump
timer.
Do not use an extension cord. Do not plug the device into an electric power outlet. Turn off the
differential circuit breaker beforehand. Ensure that the controller switches off when the filtration
pump stops.
CHLORINATION CELL (Length= 22,5 cm)
2
Install the cell in-line horizontally and after all the other devices of treatment, cleaning or heating
(just before the water jet).
Install successively the watertightness seals, then the collars and hand tighten the nuts.
Use if necessary the 63/50 reducers (supplied).
Connect the cell supply cable to the controller.
Position the terminals (brown and bleu) The terminals can be positioned on either pole
Install the lock washers and the nuts, and then tighten the nuts (using a size 10 spanner) gently until
blockage.
Use if necessary the 63/50 reducers (supplied).
3

ACCESSORY HOLDER

Install the accessory holder horizontally
After all other cleaning or heating equipment but before the chlorination cell.
Respect the water flow direction The arrow shows the direction of water flow and must be visible on
top of the holder

SALT/TEMPERATURE SENSOR

4
Plug the sensor under the device on the red RCA jack
Mount the salt/temperature sensor and tighten by hand. No Teflon Tape is needed.
22

Publicidad

Tabla de contenido
loading

Tabla de contenido