Safety instructions
This product shall only be used with the following batteries:
Art.No. 660089
Art.No. 660161
Desktop chargers shall only be connected with power adapters
supplied by the manufacturer.
Available power adapters:
Art.No. 660109
Art.No. 660093/2A
ATEX/IECEx safety instructions
Intrinsically safe classification
II 2G, II 3D
EX ib IIC T4
EX ibD 22 IP64 T50°
Charge the battery
When charging an intrinsically safe ATEX/IECEx transceiver in a
PCR Charging Rack, the rack must be version 2A or higher.
In combination with ATEX/IECEx-version, use approved battery
types only. The battery must be marked with CHAT/ATEX on the
label.
Charging parameters: Um = 5,25 V, Im = 1,25 A
Battery charging or replacement is NOT permitted in a
hazardous area.
For approved battery types, see EC Type Examination and IECEX
Scheme Certificate of Conformity and following supplements.
The document above and the EC Declaration of Conformity can
be found at http://www.ascom.com/ws/products_ws.htm and
http://www.iecex.com
Remove the battery
The rear cover holding the battery is fastened by a torx screw
that requires the special tool included in the delivery.
Removing the battery is NOT permitted in a hazardous area.
Battery
Battery ATEX/IECEx-version
Power supply unit AC/5V DC/1A
PCR Charging Rack
CE 0470
IECEx SIR 07.0033X
SIRA 07ATEX 2108X
GB
11