4- INSTALLATION OF THE UNIT

4.3- CONNECTING THE WATER AND CONDENSED WATER PIPES

4.3.1- Pipe connection

When installing the water pipes of the unit,
follow the next steps:
1 Put down two screws between the pipe
holder and the unit. Then, get down the
pipe holder (Figure 4.3).
2 Connect the pipe.
3 Install the pipe holder (Figure 4.4).
For the left-hand and rear-left-hand piping,
install the piping as shown. Bend the
connecting pipe to be laid at 43 mm height or
less from the wall.
Unit outline
Figure 4.
Fix the end of the connecting pipe.
CAUTION:
Connect the unit and, then, bend and arrange
the pipe carefully.
Do not allow the piping to let out from the
back of the indoor unit.
Be careful not to let the drain hose slack.
Insulate both of the auxiliary piping.
Bend the drain hose under the auxiliary pipe.
Figure 4.3
Do not allow the piping to let out from the
back of the unit.

4.3.2- Piping and bandaging

Wind the connecting cable, drain hose and
wiring with tape securely, evenly as shown
below.
The condensed water from rear of the unit is
gathered in PondBox and is piped out of room.
Figure 4.4
Do not put anything else in the box.
7
Connecting pipe
Connecting cable
Drain hose
Figure 4.5
Pond box
Pipe room
Connecting
pipe
Wrapping
belt
Figure 4.6