Consumables

Description
Filter bag, standard
Water evacuation hose with claw coupling
Drain tap
Coarse separator
For spare parts, see the

Warranty

The warranty period is two years and covers manufacturing defects. The warranty is
valid on condition that the machine is used in the normal way and receives the
required service. Normal wear and tear is not covered. Repairs must be carried out by
Dustcontrol or personnnel authorized by Dustcontrol. Otherwise, the warranty is void.

Troubleshooting

Problem
Motor not running.
Motor stops
immediately after
starting.
Motor runs, but no
suction.
Motor runs, but poor
suction.
24
Dustcontrol
website.
Cause
Power supply not
connected.
Incorrect fuse.
Blocked hose/inlet.
Suction hose perforated.
Clogged filter bag.
Suction hose too long or
narrow.
Hose partially blocked.
Liquids Extractor, Art.nr. 94142-I
Part No.
42190
40574
4120-4033
40594
Solution
Connect power supply.
Replace with correct
fuse.
Reverse or clean hose.
Replace hose.
Replace the bag.
Replace hose.
Reverse or clean hose.