RAS / SGS

2.5 Maintenance

Impact wrench / Ratchet screwdriver
Drive motor lubrication:
Regular lubrication is required!
Apply oil via a maintenance unit with a mist
oiler.
Without mist oiler: oil daily by hand via the
plug nipple (item 01).
In the event of longer interruptions in op-
eration,
also
lubricate
nipple (item 01).
Impact wrench
Lubricate the impact mechanism ap-
prox. every 48 working hours:
If available:
apply grease via grease nipple (item 10)
approx. every 48 working hours.
Impact wrench
Impact mechanism lubrication
2-3 times a year with oil / grease:
1. If fitted:
Loosen the oil filler screw (item 09).
2. Fill with approx. 5-10 drops of oil.
3. Tighten the oil filler screw.
Ratchet screwdriver
lubrication 2-3 times a year with oil:
1. If fitted:
Lift the rubber protection (item 12).

2.8 Troubleshooting

Problem
A
Screws do not
unscrew
B
Square bar
does not
retain the
socket span-
ner
*For troubleshooting: refer to the information in the "Technical data" chapter in part 1 of the instruction manual!
If necessary, contact our service staff, see last page.
II/6
via
the
Cause
Socket spanner worn
Air regulation adjusted incorrectly
Working pressure (flow pressure)
too low
Compressor output too small
Hose diameter too small
Socket spanner worn
Retaining ring (item 06) / Retain-
ing ball (item 07) faulty or miss-
ing
Square bar on the drive shaft
(item 05) worn
2. Lubricate the drive bush, drive shaft and
ratchet drive housing through the re-
cesses in the front of the machine or the
via the switch-over button (item 04) as
shown in Fig. 5a.

2.6 Decommissioning

Storage: Clean, dry, dust-free, not below
5° C.
Disposal: Dispose of the packaging / device
plug
/ materials used according to applicable legal
regulations.

2.7 Warranty

Basic principle: complete unit in original
condition / proof of purchase.
Material and production defects are covered
by statutory provisions.
Excluded warranty claims: Wear or ex-
pendable parts, improper use, overloading /
incorrect pressure, manipulation / inappro-
priate use, inadequate / incorrect / lack of
maintenance or lubrication, bumps / im-
pacts, dust / dirt accumulation, unauthorised
/ incorrect working procedures, incorrect
power supply, impure / insufficiently filtered
compressed air, failure to read the instruc-
tion manual, incorrect operating resources /
materials.
Remedy
Replace the socket spanner
Correct air regulation
Increase working pressure (flow
pressure) Observe maximum work-
ing pressure
Use different output rating
Use correct hose diameter
Replace the socket spanner
Contact Schneider Airsystems or
your local service partner
Contact Schneider Airsystems or
your local service partner.
*
*
*
*