2 Technical Specification

2.1 Technical Data

Flow Data
Model
BA-DME012-E
BA-DME015-E
BA-DME020-E
BA-DME025-E
BA-DME030-E
BA-DME040-E
BA-DME050-E
BA-DME060-E
BA-DME080-E
Stated flows are for operation at 7 bar g (100 psi g / 0.7 MPa g) with reference to 20ºC, 1 bar a, 0% relative water vapour pressure.
Performance
Dryer Model
BA-DME012 - 080
(1) ISO 8573-1 classifications apply when the dryer is installed with the filtration supplied
Operating Data
Model
BA-DME012 - 040
BA-DME050 - 080
Electrical Data
Supply Voltage
Connection Type
(1)
Fuse
Power
(1) Fuses are Anti surge (T), 250V, 5x20mm LBC, Breaking capacity 35A @250V, IEC60127-2, UL/CSA.
Pipe Size
Inlet
Outlet
L/s
G 1/2Ý
G 3/8Ý
11
G 1/2Ý
G 3/4Ý
15
G 1/2Ý
G 3/4Ý
19
G 1/2Ý
G 3/4Ý
25
G 1/2Ý
G 3/4Ý
31
G 3/4Ý
G 3/4Ý
40
G 1
G 1
50
G 1
G 1
61
G 1
G 1
83
Pressure Dewpoint
ISO 8573-1:2010
(Standard)
Water Classification
o
o
C
F
-40
-40
Min Operating
Max Operating
Pressure
bar g
psi g
bar g
4
58
16
4
58
13
BA-DME 012 - 040
207 - 253V 1PH 50/60Hz
IEC 60320 - C14
T500mA
65 W
Flowrate
3
3
m
/min
m
/hr
0.68
41
0.91
55
1.19
71
1.50
90
1.84
110
2.49
149
3.01
180
3.69
221
4.99
299
(Standard)
(1)
Class 2
Min Operating
Pressure
Temperature
o
psi g
C
232
5
188
5
BA-DME 050 - 080
207 - 253V 1PH 50/60Hz
IEC 60320 - C14
T500mA
3
cfm
24
32
42
53
65
88
106
130
176
Max Operating
Temperature
o
o
o
F
C
F
41
30
86
41
30
86
34W

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ba-dme080