Oase Vitronic 18 Instrucciones De Uso página 6

Ocultar thumbs Ver también para Vitronic 18:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

- English -
Installation and connection
Prerequisite
• The unit head is removed. (→ Removing the unit head)
Set-up the unit
How to proceed:
B, C
• Install the unit at least 6.6 ft (2 m) from the edge of the pond.
• Only install the unit in the permitted positions to ensure fault-free operation.
• Allow sufficient space for carrying out maintenance work.
Connect the unit
Use hoses that are suitable for a pressure of at least 14.5 psi (1 bar).
How to proceed:
D
1. Shorten the stepped hose adapter to the diameter of the hose used if necessary.
– This reduces pressure losses.
2. Connect the hose with the stepped hose adapter and secure with a hose clip.
– In the case of a stepped hose adapter with separate union nut, first push the union nut over the hose.
3. Connect the stepped hose adapter with seal to the casing.
– Connect the inlet and outlet.
– Hand tighten the stepped hose adapter.
Connect the unit to the flow-through filter.
The unit is suitable for connection to flow-through filters. Both outlet sockets are screwed to the inlet nozzles on the
flow-through filter. Adhere to the instructions for use of the flow-through filter.
How to proceed:
E
1. Unscrew the cover cap.
2. Guide the outlet sockets with flat seal through both holes in the container wall of the flow-through filter.
3. Screw the inlet nozzle with O ring onto the outlet socket and hand tighten.
4. Connect the supply hose to the inlet socket. (→ Establish connections)
Start-up
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
• Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water:
Isolate the units and installations (switch off and disconnect from the power supply) before reaching into
the water.
• Isolate the unit before starting any work.
• Secure the unit to prevent unintentional switching on.
Prerequisite
• Switch the pump on first, then switch on the UVC clarifying unit.
• Check all connections for leaks.
Switching ON/switching OFF
• Switching on: Insert the power plug into the socket.
– The unit switches on immediately.
• Switching off: Disconnect the power plug.
Check the function.
F
• The function display is lit when the UVC lamp is switched on.
• The transparent stepped hose adapters are lit when the UVC lamp is switched on.
6
23929-09-14_GA_Vitronic 18-36_US6 6
18.09.2014 10:11:38

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Vitronic 36

Tabla de contenido