Terminals
WARNING OUT Terminal
This terminal will help you to know when something
wrong has happened to the VCR during recording.
The VCR outputs a pulse signal from WARNING
OUT terminal.
COM terminal
Tape recording stops.
Note
To turn the clog detection function off, set CLOG
DETECTION to OFF on the ALARM SET menu.
WARNING OUT terminal
5 V
0 V
To reset the output signal,
press STOP x or
EJECT Z, or press the reset
button.
TAPE END OUT Terminal
When the VCR detects the tape end, the output level
becomes 0 V DC. When the buzzer is set to ON on the
DISPLAY/BUZZER/SW OUT menu, the VCR beeps
when the tape reaches its end. To resume the 5 V
output, press the operation button (EJECT Z, REC z,
FF M, REW m, PLAY B or STOP x etc.).
TAPE END OUT terminal
REC mode
Tape end
Beginning of tape
Recording
Rewind
mode
Output
signal
REPEAT REC mode
Tape end
Recording
Rewind
mode
Output
signal
2 sec.
COM terminal
Press operation
button
Stop
5 V
0 V
Beginning of tape
Recording
5 V
0 V
51