2. Installation of the gate operator
The base unit of the gate operator requires a concrete pad in order to maintain proper
stability. The concrete pad should be of the dimensions (approximately) 450 mm x 300 mm
x 200 mm (LxWxH) in order to provide adequate weight and structure to ensure a sturdy
construction.
Put the hooks into the concrete pad (for the distances between the hooks, see Fig. 3) before
it is cured.
After the concrete has cured, mount the gate operator base to the concrete pad.
Make sure that the base is properly leveled.
Check the operator and make sure it is parallel to the gate.
Alternatively, you can use wedge anchors to fix the operator.
Gate operator
Gear
Groundsill
Input
power
204 mm
DE FR EN ES
EN
Nut
Hook
Fig. 2
Fig. 3