08 | Dräger Babyleo
®
TN500
Especificaciones técnicas
Oxygen regulation (Optional)
Flow velocity over mattress surface
Operating volume in patient compartment
Noise measurement in patient compartment (Optional)
Light measurement in patient compartment (Optional)
Scale (Optional)
Ergonomic Access to Patient
Hood
5 Hand ports
2 side access panels and
front access panel
10 Grommets
Further Functionality
Views
Graphical and tabular display of trends
Lock
Timer
ClearView
Transition
Water bag holder on rear of main column.
Normal measurement range: 30 to 99 % RH
Setting range: Off, 30 to 99 % RH in steps of 1 %, AUTO
Servo-controlled Oxygen enrichment in patient compartment with
connection to central O
supply and/ or to O
2
on device
Measurement range
Normal range: 18 to 65 Vol%
Extended range: 66 to 99 Vol%
Measurement inaccuracy in normal range: ± (2,5 Vol% + 2,5 %
from reading)
O
rise time from 21 to 65 Vol%
2
<10 minutes
10 cm/s (3.94 in/s) (with a horizontal mattress tray and an air
temperature of 36 °C (96.8 °F))
Typically 40 dB(A), measured without oxygen application
Measurement range 40 to 99 dB(A)
Measurement range 3 to 999 Lux (1 to 93 fc)
Measuring range (incl. tare): 200 to 10,000 g (0.44 lb to 22 lb)
Tare weight: <= 10kg (22 lb)
Display range: 0 to 10,090 g (0 to 22 lb 2 oz)
Resolution (NAWI version): 10 g (0.022 lb)
Resolution (standard version): 1 g (1 oz)
Detail
Quick and simple mechanical opening and closing of the hood,
power supply independant, also possible when device is switched
off, softened closing, opening time typically < 2 sec
2 Jumbo-Handports per side for access to entire mattress area
plus additional hand port at the front
Hinge down all access panels for patient access for medical
interventions and primary care.
Pulling out the bed support for medical procedures and for
parents enabling close contact to their baby.
Double at each corner and single grommets at front and back of
the patient compartment
Detail
Main page, Thermomonitoring, Developmental Care, Family View
2 hours to 7 days for temperatures, heating, noise level/ light level
measurement, weight, events
Screen, height adjustment, bed tilt against accidentally adjusting
the device settings
Stopwatch and APGAR timer with alarms after 1 min, 5 min,
10 min.
Condensation management, the radiant warmer runs on a low
level to reduce condensation on the inside of the hood.
Standby operation between incubator and radiant warmer to
ensure a rapid change of operating mode without loss of heat.
In incubator operation, the radiant warmer is running on a low
level, in radiant warmer operation the convection heater is pre-
heated.
-cylinder mounted
2