Operating instructions /
Description of function
The control unit allows a variety of operating modes:
Dead man OPEN / dead man CLOSE
Pressing button
and keeping it pressed causes the
door to open until the OPEN end-of-travel position is
reached. Releasing the button causes the door to
stop. The door is closed by dead man's control, i.e.
pressing button
and keeping it pressed, until the
door reaches its CLOSE end-of-travel position. If the
button
is released during closing, the door stops
instantly.
Impulse OPEN / dead man CLOSE
By briefly pressing the button
impulse from an external impulse generator, the door
starts to open until reaching the OPEN end-of-travel
position or the door can be stopped beforehand by
pressing button . If button
is pressed again, the
door continues to open. The door is closed by dead
man's control, i.e. pressing button
pressed, until the door reaches its CLOSE end-of-
travel position. If the button
closing, the door stops instantly.
Impulse OPEN / impulse CLOSE
By briefly pressing button
or generating an impulse
from an external impulse generator the door starts to
open until reaching the OPEN end-of-travel position,
or the door can be stopped beforehand by pressing
button . By briefly pressing button
closing until reaching the CLOSE end-of-travel
position.
This operating mode demands that a safety edge
(menu 35) be installed. If the safety edge is triggered
during closing, the door stops and changes direction.
If the safety edge is triggered during opening, this has
no effect. In the case of a defect, the door can be
closed using dead man's control.
AR-mode / automatic closing
By briefly pressing button
or generating an impulse
from an external impulse generator, the door starts
opening until reaching the OPEN end-of-travel
position. Or the door was stopped prematurely using
button . Once the set hold-open time has elapsed,
there follows an early warning phase of 10 seconds,
after which time the door automatically closes.
If button
is pressed when the door is in the open
position or while it is closing, the door is immobilized
until a new impulse
or is generated.
AR-mode with shortened response time via
photocell
Function as described above, but an interruption of
the photocell causes the set hold-open time to be
terminated and the early warning phase to begin.
After the early warning phase has expired, the door
automatically closes.
OPEN-CLOSE operation
However, the receiver remains plugged into the drive
in the same operating mode like the one-way control
with the red-green traffic light (optional traffic light
control A800).
Operating sequence for external impulse generators:
Generating an impulse in the close position:
Drive starts and moves the door into the open
position
Generating an impulse during the opening:
Door continues to move without being affected
Generating an impulse in the open position:
Door closes
Generating an impulse during the closing:
Door stops and opens again
Half-opening of the door
Pressing the ½ button initiates the set half-opening of
the door (menu 32).This function is not available in
the dead man OPEN / dead man CLOSE operating
mode.
Lighting and / or early warning light
The control unit has two relay outputs allowing the
switching of lighting or the early warning light (menu
45 and 46).
Key switch function (optional)
The control unit has an input for a key switch. This
allows you to activate the following functions (menu
50):
0
or generating an
1
2
3
and keeping it
4
is released during
5
6
External command units / impulse generators
The door can be opened and closed via external
command units/impulse generators.
the door starts
Radio hand transmitter (optional)
Button: Start
First impulse:
The operator starts up and causes the door to travel
to the set OPEN or CLOSE travel limits.
Impulse generated during travel:
Door stops.
A new impulse is generated:
Door continues to travel but in the opposite direction.
½ button for half-opening:
Function as with the START button, but the door
travels to the set half-open position only.
Button: Light
The light function involves a continuous light that can
be switched on/off independent of the door action.
Key switch without function (factory
default)
Control panel on the control unit is
blocked.
All external control elements are
blocked.
Control panel on the control unit and all
external control elements are blocked.
For 10 secs. the control panel on the
control unit and all the external control
elements are active.
Switching of operating mode to impulse
OPEN / dead man CLOSE.
Half-opening of the door only.
Maintenance / Checks
For your own safety, we recommend
that prior to initial operation and
whenever required - however at least
once a year, you have the door system
tested by a specialist company.
Service display
If the control unit establishes the need for testing /
inspection, "service" shows up in the display. Contact
a specialist company.
GB