mundoclima MU-CA 100 AN Instrucciones De Uso página 15

Tabla de contenido

Publicidad

ENGLISH
ENGLISH
Except for the MU-CA 100 AN, MU-CA 150 AN, MU-CA 200 AN that can only be used as an Air
Curtain with fresh air, the rest of models on this range have the option of working either with fresh or
warm air.
We advise you to check that the unit is in perfect condition when unpacking it, as any manu-
facturing or quality defect is covered by the guarantee.
IMPORTANT: SAFETY GUIDELINES
The appliance must not be right above or below a socket.
Do not cover the unit with clothes or objects that may obstruct the airflow and cause overheating.
While in operation, the connection cable must not be in front of the air outlet.
If it is installed in the bathroom, it must be placed so that the switches or other devices of com-
mand cannot be touched for a person that be in the bathtub or shower.
There must not be any inflammable objects at less than 50 cm from the unit (such as window
curtains, etc.). Keep the inlet and outlet grilles clean. When cleaning them, disconnect the unit
from the main supply.
Do not manipulate the unit with wet hands.
The installation work must be carried out by an electrician.
IMPORTANT: THIS APPLIANCE MUST BE EARTHED.
The means of disconnection from the mains supply must have an opening distance of at least
3 mm in all poles.
To operate the unit as an Air Curtain, the maximum distance to the floor must not be greater than 3 m.
The minimum distance between the Air Curtain and the floor must be 1,8 m.
INSTALLATION
The unit must be fixed to a convenient surface, and the minimum distances shown on Fig. 1
must be kept.
To install the unit, proceed as follows:
If the spiral nuts already placed in the device are used, there must be marked the centers of
the screws (M-8) according to the table of Fig. 2 (a) and Fig. 2 (b). If the hanging fixation is used,
the centers must be marked according to the table of Fig. 3 (a) and Fig. 3 (b) and place the
screws (D) and the set squares (E). Then hang the device and to fix on the lowest part with the
screw (G).
When the included wall bracket kit is used Fig. 4 (2 pcs. for 100 models and 3 pcs. for 150/200
models) set the support (L) to the back part of the curtain with the screws provided (I). Fix the
brackets (J) to the wall to match with the brackets on the curtain (L). See dimensions Fig. 3 (a)
and Fig 3 (b). Then hang the device and fix on the lowest part with the screw (K).
ELECTRICAL CONNECTION (Fig. 5)
The MU-CA Air Curtains are installed appliances. When installing these air curtains, the stand-
ards and regulations in force in your country must be followed strictly adhered to. Within the
installation an electrical isolation switch must be present, to enable the installer to cut all sup-
ply lines.
Connect the unit to the mains supply, checking that the voltage and frequency are the same as
those indicated on the electrical rating plate. Use the cables with the number of wires and sec-
tions as indicated on the wiring diagram for every model.
15