The connection can be made either through the back or by the side of the units. In case of
connection by the side, the lid of the connections must be mounted through the cable before
carrying the connections.
Fix the cable with the clamp provided and mount the front cover.
OPERATION
REMOTE CONTROL CONNECTION
(This control is incorporated in the packaging of each air curtain)
CURTAIN MODEL
MU-CA 100 AN
MU-CA 150 AN
MU-CA 200 AN
MU-CA 100 RN-3,5
MU-CA 100 RN-6
MU-CA 100 RN-9
MU-CA 150 RN-9
MU-CA 150 RN-12
MU-CA 200 RN-18
IF CONNECTION BETWEN TWO OR MORE AIR CURTAINS OF THE SAME MODEL (MAX. 5
UNITS), PLEASE REFER TO WIRING DIAGRAM FROM Fig. 6.
NOTE: In the case of multiple connection, Installer must consider the increased number of
feeders based on the number of connected units. In order to interconnect two or more cur-
tains it is predicted that the cables can go through their interior. Fig. 7 shows a lateral cover on
which a noticeable circular opening is present. This opening allows easy breakage, thus ena-
bling the installer to feed cables to the unit.
PROTECTION AGAINST OVERHEATING
The MU-CA Air Curtains are fitted with one thermal fuse which automatically disconnects the
unit in case of overheating.
In the event of this happening please contact the official dealer in your area.
MAINTENANCE
The MU-CA Air Curtains do not need any special maintenance, but it is recommended to keep
the inlet and outlet grilles clean. Clean them with a dry cloth (avoid using solvents or abrasive
detergents). Once a year, the inside parts should be cleaned by a qualified electrician using
compressed air or a vacuum cleaner. Disconnect the unit from the mains supply before carry-
ing out this operation.
AFTER SALES SERVICE
In case of any problem with the unit, it is advised to contact your dealer. Any manipulation
of the appliance by personnel not appointed by will cancel the guarantee.
reserves the right to modify the product without prior notice.