Maintenance

CARTRIDGE REPLACEMENT

- Turn off the water supply to the faucet .
- Take off the plastic temperature indicator (1) by hand, then use the hex key to remove the set screw (2) and pull the handle
body (3) off.
- Unscrew the decorative cap (4) and retaining nut (5), making sure not to damage the threads.
- Pull out the cartridge (6) and replace it with a new ceramic cartridge.
- Reinstall the retaining nut (5) making sure the cartridge (6) is properly seated within the faucet body (7).
- Reinstall the decorative cap (4) and tighten gently by hand.
- Reinstall the handle body (3) and lock it in place using the hex key and the set screw (2). Do not over tighten.
- Reinstall the temperature indicator (1) into the handle body (3) making sure the red is on the left and the blue is on the right.
- Turn the water supply to the faucet back on .
- Operate the faucet to make sure everything works correctly and check for leaks .
QL038
Temperature indicator (1)
Decorative cap (4)
Retaining nut (5)
Cartridge (6)
Faucet Body (7)
10
Set screw (2)
Handle
Body (3)