Makita HR2652 Manual De Instrucciones página 11

Martillo combinado con recolección automática de polvo
Ocultar thumbs Ver también para HR2652:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

For HR2652/HR2653/HR2663
Optional accessory
Attach the chuck adapter to a keyless drill chuck to
which 1/2"-20 size screw can be installed, and then
install them to the tool. When installing it, refer to the
section "Installing or removing drill bit".
1
2
► 1. Keyless drill chuck 2. Chuck adapter
For HR2653T
Use the quick change drill chuck as standard equip-
ment. When installing it, refer to "changing the quick
change chuck for SDS-plus".
Hold the ring and turn the sleeve counterclockwise to
open the chuck jaws. Place the bit in the chuck as far as
it will go. Hold the ring firmly and turn the sleeve clock-
wise to tighten the chuck.
► 1. Sleeve 2. Ring
To remove the bit, hold the ring and turn the sleeve
counterclockwise.
Diamond core drilling
NOTICE:
If performing diamond core drilling
operations using "rotation with hammering"
action, the diamond core bit may be damaged.
When performing diamond core drilling operations,
always set the change lever to the
"rotation only" action.
By beating the dust on the filter inside the dust case,
you can keep the vacuum efficiency and also reduce
the number of times to dispose of the dust.
Turn the dial on the dust case three times after col-
lecting every 50,000 mm
vacuum performance declined.
1
► 1. Dust case 2. Dial
2
position to use
11 ENGLISH
Beating dust on the filter
CAUTION:
Do not turn the dial on the dust
case while the dust case is removed from the
dust collection system. Doing so may cause dust
inhalation.
CAUTION:
Always switch off the tool when
turning the dial on the dust case. Turning the dial
while the tool is running may result in the loss of
control of the tool.
3
NOTE: 50,000 mm
of dust equivalents to drilling 10
holes of ø10 mm and 65 mm depth (14 holes of ø3/8"
and 2" depth).
Disposing of dust
CAUTION:
Always be sure that the tool is
switched off and unplugged before carrying out
any work on the tool.
CAUTION:
Be sure to wear dust mask when
disposing of dust.
CAUTION:
Empty the dust case regularly
before the dust case becomes full. Failure to do so
may decrease the dust collection performance and
cause dust inhalation.
CAUTION:
The performance of dust collection
decreases if the filter in the dust case become
clogged. Replace the filter with new one after
approximately 200 times of dust fulfillment as a
guide. Failure to do so may cause dust inhalation.
3
of dust or when you feel the
2
1

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Hr2653Hr2653tHr2663

Tabla de contenido