GB
If necessary repeat the procedure also for the other buttons.
On the receiver it is also possible to disable the remote programming
function by closing the JP1 jumper (fig. 1),
ADVANCED PROGRAMMING (P2)
Output 2, button P2. This output (second channel) is only available for
certain applications:
1. Impulse output. (Fig. 1 button P2)
- Proceed as described in the "Standard Programming" section, but use
the P2 button on the receiver.
2. Step-by-step output. (Fig. 1 button P2)
- During the programming procedure, press the P2 button twice instead
of once as described in the "Standard programming" section.
- LED2 will emit 5 series of 2 blinks.
- While the LED is blinking, press the button on the transmitter corre-
sponding to the code to be memorized.
- The LED will light up steadily for a few seconds indicating that the lear-
ning procedure has been successfully completed. The output correspon-
ding to the P2 button is now step-by-step.
If there is no power supply and the output was active, it deactivates.
3. Timer output. (Fig. 1 button P2)
- During the programming stage, press the P2 button 3 times.
- LED2 will emit 5 series of 3 blinks.
- While the LED is blinking, press the button on the transmitter corre-
sponding to the code to be memorized.
- The LED2 will light up steadily for a few seconds indicating that the
learning procedure has been successfully completed. The output corre-
sponding to the P2 button is now a timer. The time of the timer is not
adjustable and is set to about 30 seconds.