CHANGING THE OUTPUT OPERATING MODE
The receiver outputs are able to operate in one of the following modes:
PULSE: the relay is activated for about 1 second whenever it reads a
card.
STEPPING: the first time the card is passed the relay closes the contact
and it remains active until the next time a code present in the memory is
read.
TIMER: in this mode, when a code present in the memory is read, the
output is activated for 30 seconds.
If the system includes a PASSO keypad, the timer time setting can be
modified from 2 to 255 seconds (see PASSO manual).
The mode selected refers to the individual output; all the codes saved
previously or subsequently will have the operating mode chosen.
Procedure:
- Press the reader button and the red LED comes on (det. 3 and 4 in fig.
1).
- Pass the MASTER CARD over the reader and the LED will start to
flash.
- Press the button (det. 3 in fig. 1) several times to choose one of the
following settings:
1 Flash = to set OUT1 in PULSE mode.
2 Flashes = to set OUT1 in STEPPING mode.
3 Flashes = to set OUT1 in TIMER mode (30").
4 Flashes = to set OUT2 in PULSE mode.
5 Flashes = to set OUT2 in STEPPING mode.
6 Flashes = to set OUT2 in TIMER mode (30").
- Pass the MASTER CARD over the reader to confirm and quit the
programming function.
37