Adjusting the locking mechanism:
1. Depressurise the hose and retract until
the stopper (item 04) is resting against
the stop.
2. Unscrew the screws (item 07).
3. Remove the cover cap (item 06).
4. Adjust the locking mechanism according
to the instructions in the illustration for
the relevant device:
SLA 8A (Fig. 5a)
SLA 9A and SLA 10A (Fig. 5b)
1= Locking mechanism on
- Strain on hose is relieved
2= Locking mechanism off
- Hose under constant strain
11
Troubleshooting
Observe the safety instructions and maintenance instructions!
Problem
A
Hose does not
retract fully
B
Locking mechanism
does not work
C
Hose retractor leak-
ing
*For troubleshooting: refer to the information in the "Technical data" chapter"!
***For troubleshooting: read chapter: "Commissioning"!
If necessary, contact our service staff, see last page.
12
Spare parts service
Visit
our
website
tems.com/td/ for the latest version of all ex-
ploded drawings and spare parts lists for our
products. If you have any special questions,
please consult the Schneider Airsystems Ser-
vice centre in your country (addresses in the
service appendix) or your local dealer.
Cause
Hose retracted unevenly
Insufficient spring tension
Spare hose too heavy
Hose stopper displaced
Hose retractor attached incor-
rectly
Hose released too quickly
Locking unit damaged
Incorrect locking mechanism
setting
Damaged hose
Loose hose clamps
Seal on rotary element worn
www.schneider-airsys-
5. Attach the cover cap (item 06) using the
screws (item 07)
9
Maintenance
Keep the air hose free of dust, grease and
dirt.
10
Decommissioning
Storage: Clean, dry, free from dust, above
5° C.
Disposal: Dispose of packaging / machine
according to valid statutory regulations.
Remedy
X
Unroll the hose and retract even-
ly
X
Replace the spring
X
Use a suitable spare hose
X
Move the hose stopper to the
correct position
X
See Assembly
X
Slowly pull out the hose to
the locking position
X
Replace the locking unit
X
Adjust locking mechanism
(Fig. 5a SLA8A,
Fig. 5b SLA9A SLA10A)
X
Replace hose
X
Secure hose clamps or replace
X
Replace the rotary element seal
13
Warranty conditions
Basis for warranty claims: complete unit
in original condition/proof of purchase.
According to legal provisions, you re-
ceive the following warranty against
material and manufacturing defects:
private use only: 2 years,
commercial use: 1 year.
GB
SLA
*
*
***
***
***