EyeVolution
12. Troubleshooting
Fault
Device shows no
function
LED lights up, electronics
without function
Rotary plate without
function
Time programmes can
not be activated
26
MAX
®
Cause
Incorrect mains
connection
Main switch off
Internal cabling is
defective
Plug-in power supply
unit is defective
Electronics are defective
Function deactivated
Device cover is open
Cable connection to
rotary motor (16) is
defective
Rotary motor (16) is
defective
Electronic module is
defective
Motor adapter (25)
rotates continuously
Main switch off
Device cover is open
Internal cabling is
defective
Troubleshooting
Check mains connection
Switch on main switch
Internal cabling must be
checked by a specialist.
Replace the plug-in
power supply unit
Electronics must be
checked by a specialist
Activate with pressure
switch (5)
Close cover (12)
Examine the cabling
The motor must be
examined by a special-
ist, and replaced if
necessary
The electronics must be
examined by a special-
ist, and replaced if
necessary
Tighten the motor
adapter threaded pin
Switch on the device
Close cover (12)
Internal cabling must be
checked by a specialist